Positioner Action Change
(4700P/4800P Only)
Whenever it becomes necessary to change positioner action from direct to reverse or vice
versa, it is important to be familiar with the following steps.
To remove or install the cam safely, the valve position must correspond to the low signal line on
lobe.
The positioner supply line, the vent and the lever S/A must be reversed.
From Air to Open / Direct to Air to Open/Reverse
1. Perform Steps 1 and 2 from Cam Lobe Change38 for Air to Open/Direct Acting Positioner.
Cam is now removed.
2.
Proceed to Field Mounting and Calibration section for Air to Open/Reverse Acting
Positioner and proceed as stated.
From Air to Open / Reverse to Air to Open/Direct
1. Perform Steps 1, 2 and 3 from “Cam Lobe Change” on page 38 for Air to Open/Reverse
Positioner. Cam is now removed.
2.
Slowly reduce pressure applied to actuator to zero. (If handwheel was used to place
valve in open position back it off completely.) Valve is now closed. Remove independent
regulated air line from actuator.
3. Proceed to Field Mounting and Calibration section for Air to Open/Direct Acting Positioner
and proceed as stated.
From Air to Close / Direct to Air to Close/Reverse
1. Perform Steps 1 and 2 from “Cam Lobe Change” on page 38 for Air to Close/Direct Acting
Positioner. Cam is now removed.
2.
Proceed to Field Mounting and Calibration section for Air to Close/Reverse Acting
Positioner and proceed as stated.
From Air to Close / Reverse to Air to Close/Direct
1. Perform Steps 1, 2 and 3 from “Cam Lobe Change” on page 38 for Air to Close/Reverse
Acting Positioner. Cam is now removed.
2.
Slowly reduce pressure applied to actuator to zero. (If handwheel was used to place
valve in closed position back it off completely.) Valve is now open. Remove independent
regulated air line from actuator.
3. Proceed to Field Mounting and Calibration section for Air to Close/Direct Acting Positioner
and proceed as stated.
Содержание Masoneilan 4700P
Страница 16: ...2021 Baker Hughes Company All rights reserved 16 Baker Hughes Figure 5 87 88 Actuator...
Страница 30: ...2021 Baker Hughes Company All rights reserved 30 Baker Hughes Figure 12 FM Installation...
Страница 32: ...2021 Baker Hughes Company All rights reserved 32 Baker Hughes Figure 14 ATEX Installation...