Installation
Installation
39
3. Outdoor unit installation (Side Discharge Unit)
4.1 Service space for outdoor unit
4.2 Bolt pitch
4.3 Install the Unit
Since the gravity center of the unit is not at its physical center, so please be careful when lifting it with a sling.
Never hold the inlet of the outdoor unit to prevent it from deforming.
Do not touch the fan with hands or other objects.
Do not lean it more than 45, and do not lay it sidelong.
Make concrete foundation according to the specifications of the outdoor units.
Fasten the feet of this unit with bolts firmly to prevent it from collapsing in case of earthquake or strong wind.
More than 60cm
More than 30cm
More than 60cm
More than 200cm
Air inlet
Air inlet
More than 30cm
Air outlet
(Wall or obstacle)
Maintain channel
Model
A
B
D
36
673
403
410
48
673
403
410
60
634
404
415
A
B
D
Содержание BSBSI36CTM
Страница 5: ...External Appearance General Information 3 2 External Appearance 2 1 Indoor Units Duct ...
Страница 14: ...Service Space 12 Duct Type 3 Service Space Ensure enough space required for installation and maintenance ...
Страница 15: ...Wiring Diagrams 13 4 Wiring Diagrams BSBSIE36CTM BSBSIE48CTM BSBSIE60CTM ...
Страница 22: ...Field Wiring 20 Duct Type 10 Field Wiring ...
Страница 25: ...Dimensions 23 Outdoor Units Model Unit mm W D H W1 A B BSBSIC60CTM 952 415 1333 1045 634 404 ...
Страница 28: ...Wiring Diagrams 28 Outdoor Units 4 Wiring Diagrams BSBSIC36CTM BSBSI48CTM BSBSIC60CTM ...
Страница 42: ...Installation Installation 43 ...
Страница 82: ...Troubleshooting Electrical Control System 85 ...