background image

The word "spa" is taken from a town in the province of Liege, Belgium where mineral springs 
were favored for centuries by notables and royalty, including the Russian Czar Peter the 
Great and German Kaiser William II.

However, the use of mineral springs for therapeutic purposes dates back to the 5th Century 
B.C., when hot springs in Greece and the Aegean Islands served as healing clinics.   At one 
of these clinics on the Island of Cos, the Greek physician Hippocrates practiced medicine for 
a while and wrote extensively on hydrotherapy.

The Romans, after a day of conquering the world, retreated to the pleasures of spas.   In fact, 
many well-preserved spas built by the Romans still exist in places as far apart as Bath, 
England; Baden, Switzerland; and Tiberias, Israel.   After the fall of Rome in the 5th Century 
A.D., the number of spas decreased.   It was not until the Renaissance, mysteriously 
enough, that they once again became numerous.   Which raises the question:   Does the use 
of spas result in great thinking, or do great thinkers resort to the use of spas?

A new Baja Spa is the modern machine for today's great thinkers.   It blends many advanced 
features to help you enjoy the benefits of warm water for recreation and therapy.

Baja Products, Ltd. originated the acrylic spa in 1972, and our experience plus dedication 
assure you of the highest quality components and materials of construction.

We wish you years of enjoyment and relaxation with your new spa.   Please take a few 
minutes to read the safety instructions and operating features described in this manual.

A BRIEF HISTORY OF SPAS

2

SAFETY INSTRUCTIONS

When installing and using this electrical equipment, basic safety precautions should always be 
followed, including the following:

 

1

 

   

READ AND FOLLOW ALL INSTRUCTIONS.

 

2.

WARNING

 - 

To reduce the risk of injury, do not permit children to use this product 

unless they are closely supervised at all times.

   
3.               A wire connector is provided on this unit to connect a minimum No. 8 AWG (8.4         

2

                     mm ) solid copper conductor between this unit and any metal equipment, metal 
                     enclosures of electrical equipment, metal water pipe, or conduit within 5 feet 
           (1.5 mm) of the unit.

4.  

(For Cord-Connected/Convertible Units)

 
  

DANGER - Risk of injury.

 

a)   Replace damaged cord immediately.
b)   Do not bury cord.
c)   Connect to a grounded, grounding type receptacle only.

Содержание Whitewater XS

Страница 1: ...Please read and follow all instructions before installing operating or enjoying your spa Please refer to the operational video that is supplied with spa Save these instructions for future reference RE...

Страница 2: ...HTSCAPE LED LIGHTING SYSTEM PAGE 11 IN HOUSE CONTROL PANEL PAGE 12 BAJA BREEZE AROMATHERAPY PAGE 12 JET FILTER OPERATION PAGE 12 WINTERIZING YOUR SPA PAGE 13 SUMMERIZING YOUR SPA PAGE 13 REGULAR SPA M...

Страница 3: ...Spa is the modern machine for today s great thinkers It blends many advanced features to help you enjoy the benefits of warm water for recreation and therapy Baja Products Ltd originated the acrylic...

Страница 4: ...alternative a spa may be installed within 5 feet of metal surfaces if each metal surface is permanently connected by a minimum No 8 2 AWG 8 4 mm solid copper conductor to the wire connector on the te...

Страница 5: ...betes should consult a physician before using a spa f Persons using medication should consult a physician before using a spa since some medication may induce drowsiness while other medication may affe...

Страница 6: ...any electrical wires 7 In selecting the ideal outdoor location for your spa we suggest you take into consideration the following a The view you ll have from the spa b The proximity to your home for ch...

Страница 7: ...NING Improper electrical connections or conductor sizing may cause the Equipment Module to operate improperly create the potential for an electrical hazard and may void the warranty CAUTION Use only a...

Страница 8: ...it Interrupter s GFCI s are provided with a LINE neutral connection lead Since the GFCI itself is a 120 volt device this wire must be connected to the neutral buss bar in order for the GFCI to functio...

Страница 9: ...r to the Equipment Module 8 9 10 11 Check for leaks Although spas are fully checked at factory shipping delivery Might cause a leak Call your dealer or Baja directly if there is a problem Circulation...

Страница 10: ...t of light shows Use the spa s light key to turn NIGHTSCAPE on and off When you turn NIGHTSCAPE off and then on again within five seconds it advances to the next show When you turn NIGHTSCAPE off and...

Страница 11: ...st the minutes from 00 to 59 Press the Program key to confirm the new setting and wait until controller resets Temperature Time Spa will be programmed 2 SPA PROGRAMMING PARAMETERS 1 2 3 00 1 00 1 Baja...

Страница 12: ...on through the color spectrum Each color cycle takes approximately 1 minute SLOW RANDOM COLOR Colors step from one color to the next in random order Each color lasts approximately 10 15 seconds FAST R...

Страница 13: ...with fresh aromatherapy spa scents To install Baja Breeze scents simply 1 Turn off the Booster pump 2 Unscrew Baja Breeze aromatherapy cap located on top of spa 3 Place aromatherapy scents pack or bag...

Страница 14: ...sors If the sensor registers an ambient temperature below 59 F the systems Smart Winter Mode will activate This mode once activated will continue for a period of 24 hours The system will activate any...

Страница 15: ...CLEAN FILTER IF NECESSARY CLEAN FILTER CARTRIDGE CLEAN THE INSULATED SPA COVER TEST THE GFCI DRAIN THE SPA COMPLETELY REFILL WITH WATER AND REPLENISH CHEMICALS WHILE THE SPA IS EMPTY CLEAN WITH ANONA...

Страница 16: ...a component is being supplied with the proper voltage if a fuse has blown or by simply pressing a switch if the complete system is being supplied with voltage from the breaker panel The following inf...

Страница 17: ...If 3 flashing dots appear below the temperature display an error has occurred and a service call is needed If the actual spa water temperature greatly differs from the displayed temperature or the dis...

Страница 18: ...l in the LEFT CORNER position on models 1044 67 68and in RIGHT SIDE panel position on models 1042 46 Black drain valve located to the right of the equipment pack attached to clear hose with a hose cla...

Страница 19: ...er Condition Care _________________________ _________________________ Skirting Condition Care _________________________ _________________________ Overall Spa Appearance _________________________ _____...

Страница 20: ...NOTES SPA SCHEMATIC 19...

Страница 21: ...Baja Products Ltd 4065 North Romero Road Tucson AZ 85705 Customer Service 800 845 2252 Ext 23 E Mail Address Info bajaspa com Date _________Model ____________________ Serial Number BPL03 05 200...

Отзывы: