background image

TROUBLESHOOTING VDS

SYSTEM FUSE

 - This fuse 

protects the printed circuit board.

Input voltage connected 
incorrectly, defective transformer. 

Call your local dealer.

VDS INDICATOR ILLUMINATED

POSSIBLE PROBLEM

HIGH-LIMIT TRIPPED

 - Over 

temperature condition, do not 
enter spa .

Restricted flow of water caused by 
dirty filter, water shutoff valve not 
fully open, improperly adjusted 
jets, or debris in plumbing. 

Call 

your local dealer.

JET 1 FUSE

 - Protects the 

primary pump.

Restricted flow of water, faulty 
pump or severe weather/electrical 
storm. 

Call your local dealer or 

qualified technician.

JET 2 FUSE

 - Protects the 

secondary pump.

Restricted flow of water, faulty pump 
or severe weather or electrical 
storm. 

Call your local dealer or 

qualified technician.

CIRC./OZONE FUSE

 - 

Protects a circulation pump 
and/or ozonator.

Restricted flow of water, faulty 
pump and/or ozonator or severe 
weather/electrical storm. 

Call your 

local dealer or qualified 
technician.

ACCESSORY FUSE

 -Protects 

spa fiber optics.

Faulty fiber optic system or severe 
weather/electrical storm. 

Call your 

local dealer or qualified 
technician.

Your particular system may not include all of the components listed. If a component continually blows 
the fuse, the component may be defective. Contact your local spa dealer or a qualified technician.  

VDS INDICATOR ILLUMINATED

POSSIBLE PROBLEM

Your system is equipped with Hydro-Quip’s exclusive, Visual Diagnostic System, your control will do the  
troubleshooting for you. VDS consist of control-mounted indicators and (if equipped) HydroQuip Smart 
Cords.  You will know at a glance if a component is being supplied with the proper voltage, if a fuse has 
blown or (by simply pressing a switch) if the complete system is being supplied with voltage from the 
breaker panel. The following information will guide you through the Visual Diagnostic System:

VDS-VISUAL DIAGNOSTIC SYSTEM 

The cords that connect the vital components of your spa to the control have been equipped with internal 
diagnostic indicators. Whenever a component is operating, that components corresponding plug 
connection will illuminate to let you know that proper voltage is being supplied. 

As a diagnostic tool, if a component is not functioning, a simple glance will tell you if proper voltage is being 
supplied to that component. If the plug is illuminated but the component is not operating, the component 
may be defective.

If the plug is not illuminated, the components fuse indicator should be illuminated. If it is not, use the power 
test switch to ensure that voltage is being supplied to the system.     

SMART CORD CONNECTION 

TE

E

R

H A

N

O

 

u

2 F

e

et

J  

s

i

A B

e

u

*

o

s

r  l

F

we

L

t r

d

T i

i

 

H

m

 

i

e

h

p

i

p

g

t

s

F

Je  

 

e

1 u

r

 n

Cu

s

* i

/O

e

zo

F

.

e

c

s

a

u

t

 

s e

l

S t

s i

g

c

 

o

V

n

m

Di

i a

y

f

VDS

f

t

i

f

g  

 

l

V

h

I

 

D

i

a

 

S

,

e

l

ref

l u

i

a e

m

t

 

o

nt

i

d

 

w

M

a

O

u

o  

a

e s

n

f

 

r

n r

d

l

et i

s

a

e

F

ys

e

u

S

 

m

s

t

u

A

F

x  

e

*

us

.

o

ti

l

a

*Op

n

*Pump 3 Fuse

Pump 2 Fuse

*Air Blower Fuse

High Limit Tripped

Pump 1 Fuse

*Circ./Ozone Fuse

Visual Diagnostic

 

System

f

VDS

f

If a VDS light is 
illuminated, refer to 
Owners Manual for 
details

System Fuse

*Aux. Fuse

*Optional

WE

R

PO
C

L

TR

ON

O

WIT

CH

S

e t

 

a

r

p

o

f

R

 

er

i n

e

o O

t
i

t

an

 o  

st

ua

r e

n

M

l

g

f

a

an

o

t o

d p

n

 

r

al

e

i

o

 

e

es

p

du

r c

r

p 1

Pum

P

2

um

i

)

(

na

t o

l

Op

r

Ai

p

P

 

3

um

x

A

.

u

t

L g

i h

o

Oz

ne

C rc

.

i

x

A

.

u

15

Содержание Whitewater XS

Страница 1: ...Please read and follow all instructions before installing operating or enjoying your spa Please refer to the operational video that is supplied with spa Save these instructions for future reference RE...

Страница 2: ...HTSCAPE LED LIGHTING SYSTEM PAGE 11 IN HOUSE CONTROL PANEL PAGE 12 BAJA BREEZE AROMATHERAPY PAGE 12 JET FILTER OPERATION PAGE 12 WINTERIZING YOUR SPA PAGE 13 SUMMERIZING YOUR SPA PAGE 13 REGULAR SPA M...

Страница 3: ...Spa is the modern machine for today s great thinkers It blends many advanced features to help you enjoy the benefits of warm water for recreation and therapy Baja Products Ltd originated the acrylic...

Страница 4: ...alternative a spa may be installed within 5 feet of metal surfaces if each metal surface is permanently connected by a minimum No 8 2 AWG 8 4 mm solid copper conductor to the wire connector on the te...

Страница 5: ...betes should consult a physician before using a spa f Persons using medication should consult a physician before using a spa since some medication may induce drowsiness while other medication may affe...

Страница 6: ...any electrical wires 7 In selecting the ideal outdoor location for your spa we suggest you take into consideration the following a The view you ll have from the spa b The proximity to your home for ch...

Страница 7: ...NING Improper electrical connections or conductor sizing may cause the Equipment Module to operate improperly create the potential for an electrical hazard and may void the warranty CAUTION Use only a...

Страница 8: ...it Interrupter s GFCI s are provided with a LINE neutral connection lead Since the GFCI itself is a 120 volt device this wire must be connected to the neutral buss bar in order for the GFCI to functio...

Страница 9: ...r to the Equipment Module 8 9 10 11 Check for leaks Although spas are fully checked at factory shipping delivery Might cause a leak Call your dealer or Baja directly if there is a problem Circulation...

Страница 10: ...t of light shows Use the spa s light key to turn NIGHTSCAPE on and off When you turn NIGHTSCAPE off and then on again within five seconds it advances to the next show When you turn NIGHTSCAPE off and...

Страница 11: ...st the minutes from 00 to 59 Press the Program key to confirm the new setting and wait until controller resets Temperature Time Spa will be programmed 2 SPA PROGRAMMING PARAMETERS 1 2 3 00 1 00 1 Baja...

Страница 12: ...on through the color spectrum Each color cycle takes approximately 1 minute SLOW RANDOM COLOR Colors step from one color to the next in random order Each color lasts approximately 10 15 seconds FAST R...

Страница 13: ...with fresh aromatherapy spa scents To install Baja Breeze scents simply 1 Turn off the Booster pump 2 Unscrew Baja Breeze aromatherapy cap located on top of spa 3 Place aromatherapy scents pack or bag...

Страница 14: ...sors If the sensor registers an ambient temperature below 59 F the systems Smart Winter Mode will activate This mode once activated will continue for a period of 24 hours The system will activate any...

Страница 15: ...CLEAN FILTER IF NECESSARY CLEAN FILTER CARTRIDGE CLEAN THE INSULATED SPA COVER TEST THE GFCI DRAIN THE SPA COMPLETELY REFILL WITH WATER AND REPLENISH CHEMICALS WHILE THE SPA IS EMPTY CLEAN WITH ANONA...

Страница 16: ...a component is being supplied with the proper voltage if a fuse has blown or by simply pressing a switch if the complete system is being supplied with voltage from the breaker panel The following inf...

Страница 17: ...If 3 flashing dots appear below the temperature display an error has occurred and a service call is needed If the actual spa water temperature greatly differs from the displayed temperature or the dis...

Страница 18: ...l in the LEFT CORNER position on models 1044 67 68and in RIGHT SIDE panel position on models 1042 46 Black drain valve located to the right of the equipment pack attached to clear hose with a hose cla...

Страница 19: ...er Condition Care _________________________ _________________________ Skirting Condition Care _________________________ _________________________ Overall Spa Appearance _________________________ _____...

Страница 20: ...NOTES SPA SCHEMATIC 19...

Страница 21: ...Baja Products Ltd 4065 North Romero Road Tucson AZ 85705 Customer Service 800 845 2252 Ext 23 E Mail Address Info bajaspa com Date _________Model ____________________ Serial Number BPL03 05 200...

Отзывы: