Jet 1 Key:

 

Press this key once to turn Pump 1 onto Low speed, press this key 

a second time to turn Pump 1 onto High speed, a third press will turn the pump 
off. A built-in timer will shut the pump off after 20 minutes of operation unless 
done so manually. The Pump 1 Icon will appear in the upper LCD window while 
the pump is running in High speed and flash while it is in Low speed. 

Jet 2 Key:

 

Press this key once to turn Pump 2 onto High speed, a second press 

will turn the pump off. A built-in timer will shut the pump off after 20 minutes of 
operation unless done so manually. The Pump 2 Icon will appear in the upper 
LCD window while the pump is running in High speed (WhiteWaterXS™ Only).

LIGHT KEY

JET 2 KEY
JET 1 KEY

JET 1 ICON
JET 2 ICON

LIGHT ICON

FILTER ICON
PROGRAM ICON
HEATER ON ICON
TEMP. SET ICON
ECONOMY ICON

PROGRAM KEY

ECONOMY KEY

TEMP. SET KEYS

Light/Enter Key:

 

Press this key to turn the light on, a second press will turn 

the light off.  The light will automatically shut off after 2 hours. The Light Icon will 
appear while the light is on.  Lights are preprogrammed with an assortment of light 
shows. Use  the spa's light key to turn 

NIGHTSCAPE

 on and off. When you turn 

NIGHTSCAPE

 off and then on again within five seconds, it advances to the next 

show.  When you turn  

NIGHTSCAPE

 off and leave it off for more then five 

seconds, it “remembers” the last show you selected.  The next time you turn 

NIGHTSCAPE

 on, it will display the same show. (See page 11 for show

 

schedule) 

Temperature Set Keys:

 

Press the Up arrow key to increase the desired 

temperature. Press the Down arrow key to decrease the temperature. The 
temperature can be adjusted in 1°F increments from 59°F to 104°F. The new 
setting will remain on the display for 5 seconds as a confirmation. During this time 
the Temp. Set icon will appear to let you know this is the desired and not the actual 
temperature. After 5 seconds, the display will return to the current temperature 
reading. When the temperature drops to 1°F below the set temperature, the heater 
will be turned on until the temperature is 1°F above the set temperature. The 
Heater On icon will appear while the heater is on and flash when there is a call for 
heat and the heater has not yet been activated.

SPA CONTROLLER FUNCTIONS 

Default System Operation:

 When power is applied, or there is a temporary loss of power, the system will initiate 

its default programming. 

9

Содержание Whitewater XS

Страница 1: ...Please read and follow all instructions before installing operating or enjoying your spa Please refer to the operational video that is supplied with spa Save these instructions for future reference RE...

Страница 2: ...HTSCAPE LED LIGHTING SYSTEM PAGE 11 IN HOUSE CONTROL PANEL PAGE 12 BAJA BREEZE AROMATHERAPY PAGE 12 JET FILTER OPERATION PAGE 12 WINTERIZING YOUR SPA PAGE 13 SUMMERIZING YOUR SPA PAGE 13 REGULAR SPA M...

Страница 3: ...Spa is the modern machine for today s great thinkers It blends many advanced features to help you enjoy the benefits of warm water for recreation and therapy Baja Products Ltd originated the acrylic...

Страница 4: ...alternative a spa may be installed within 5 feet of metal surfaces if each metal surface is permanently connected by a minimum No 8 2 AWG 8 4 mm solid copper conductor to the wire connector on the te...

Страница 5: ...betes should consult a physician before using a spa f Persons using medication should consult a physician before using a spa since some medication may induce drowsiness while other medication may affe...

Страница 6: ...any electrical wires 7 In selecting the ideal outdoor location for your spa we suggest you take into consideration the following a The view you ll have from the spa b The proximity to your home for ch...

Страница 7: ...NING Improper electrical connections or conductor sizing may cause the Equipment Module to operate improperly create the potential for an electrical hazard and may void the warranty CAUTION Use only a...

Страница 8: ...it Interrupter s GFCI s are provided with a LINE neutral connection lead Since the GFCI itself is a 120 volt device this wire must be connected to the neutral buss bar in order for the GFCI to functio...

Страница 9: ...r to the Equipment Module 8 9 10 11 Check for leaks Although spas are fully checked at factory shipping delivery Might cause a leak Call your dealer or Baja directly if there is a problem Circulation...

Страница 10: ...t of light shows Use the spa s light key to turn NIGHTSCAPE on and off When you turn NIGHTSCAPE off and then on again within five seconds it advances to the next show When you turn NIGHTSCAPE off and...

Страница 11: ...st the minutes from 00 to 59 Press the Program key to confirm the new setting and wait until controller resets Temperature Time Spa will be programmed 2 SPA PROGRAMMING PARAMETERS 1 2 3 00 1 00 1 Baja...

Страница 12: ...on through the color spectrum Each color cycle takes approximately 1 minute SLOW RANDOM COLOR Colors step from one color to the next in random order Each color lasts approximately 10 15 seconds FAST R...

Страница 13: ...with fresh aromatherapy spa scents To install Baja Breeze scents simply 1 Turn off the Booster pump 2 Unscrew Baja Breeze aromatherapy cap located on top of spa 3 Place aromatherapy scents pack or bag...

Страница 14: ...sors If the sensor registers an ambient temperature below 59 F the systems Smart Winter Mode will activate This mode once activated will continue for a period of 24 hours The system will activate any...

Страница 15: ...CLEAN FILTER IF NECESSARY CLEAN FILTER CARTRIDGE CLEAN THE INSULATED SPA COVER TEST THE GFCI DRAIN THE SPA COMPLETELY REFILL WITH WATER AND REPLENISH CHEMICALS WHILE THE SPA IS EMPTY CLEAN WITH ANONA...

Страница 16: ...a component is being supplied with the proper voltage if a fuse has blown or by simply pressing a switch if the complete system is being supplied with voltage from the breaker panel The following inf...

Страница 17: ...If 3 flashing dots appear below the temperature display an error has occurred and a service call is needed If the actual spa water temperature greatly differs from the displayed temperature or the dis...

Страница 18: ...l in the LEFT CORNER position on models 1044 67 68and in RIGHT SIDE panel position on models 1042 46 Black drain valve located to the right of the equipment pack attached to clear hose with a hose cla...

Страница 19: ...er Condition Care _________________________ _________________________ Skirting Condition Care _________________________ _________________________ Overall Spa Appearance _________________________ _____...

Страница 20: ...NOTES SPA SCHEMATIC 19...

Страница 21: ...Baja Products Ltd 4065 North Romero Road Tucson AZ 85705 Customer Service 800 845 2252 Ext 23 E Mail Address Info bajaspa com Date _________Model ____________________ Serial Number BPL03 05 200...

Отзывы: