51
51
TROUBLESHOOTING
SYMPTOM
POSSIBLE CAUSE (S)
CORRECTIVE ACTION
The Blade Drive Motor
Does Not Work
1. E-stop pushed.
2. No power at the electrical
outlet
3. Motor burned out.
1. Twist the button (cw) to reset
or replace the switch.
2. Have electrician check
breaker or fuses.
3. Have motor repaired or
replaced.
Excessive Blade
Breakage
1. Incorrect blade tension.
2. Incorrect speed or feed.
3. Material loose in vise.
4. Blade rubs on wheel flange.
5. Teeth too coarse for material.
6. Teeth in contact with the
material before the saw is
started.
7. Misaligned guides.
8. Blade too thick for wheel
diameter.
9. Cracking of blade weld.
1. Adjust to where blade just
does not slip on wheel.
2. Consult machine chart or
handbook.
3. Clamp work securely.
4. Adjust the wheel alignment.
5. Contact Baileigh Industrial for
recommended blade type.
6. Contact material after blade
has been started.
7. Adjust as necessary.
8. Select a thinner blade (.035”
x .75” recommended).
9. Make longer annealing cycle
Teeth Ripping from Blade
1. Tooth too coarse for work.
2. Too heavy feed / too slow
feed.
1. Use a fine tooth blade.
2. Increase feed pressure and /
or speed.
WARNING:
Make sure the electrical disconnect is OFF before working on
the machine.
Содержание BS-712MS
Страница 17: ...14 14 OVERALL DIMENSIONS...
Страница 18: ...15 15 GETTING TO KNOW YOUR MACHINE A B C D E F G H I K J L...
Страница 32: ...29 29...
Страница 46: ...43 43 PARTS DIAGRAM A...
Страница 47: ...44 44 PARTS DIAGRAM B...
Страница 52: ...49 49 WIRING DIAGRAM MAGNETIC SWITCH COOLANT PUMP MOTOR 110V POWER SOURCE LIMIT SWITCH BLACK WHITE GREEN...
Страница 58: ...55 55 NOTES...
Страница 59: ...56 56 NOTES...