Six Month Maintenance
•
Do a continuity check of the safety circuit
Machine Lubrication
•
Ball bearings on the blade guide assemblies and the blade wheels are permanently sealed
and require no further lubrication.
•
Lightly lubricate the vise screw with a #2 lubricating grease.
Accessing and Cleaning the Coolant System
1. Disconnect power from the saw
2. Remove the vinyl hose (AB) from the strainer basket and pull off of the drain fitting.
3. Carefully remove the tank from the base of the saw.
4. Remove the strainer basket (AC) and pour out the old coolant from the tank.
5. Wash out any dirt and debris.
6. Clean and replace the strainer basket.
7. Refill the tank with coolant to 80% capacity.
8. Place the tank back into the base and re-connect the drain hose.