BAGRAM STX-1797 Скачать руководство пользователя страница 6

6

www.stairslight.com

LED lights (spots)

Another way to backlight the stairs is to place a small LED light (spot) on the wall above each 

step, Lights must be adjusted to a voltage of 12V. We recommend the use of dimmable lights — then 

you will be able to backlight the stairs, and smoothly to illuminate each step. 

If possible, place the lights above each step — this ensures a smooth animation effect. If there 

is a platform  -  you can add 1-3 lights to enhance the effect and treat it  as additional step.

The diagram above shows the connection of the controller toa staircase with 19 steps and two 

handrails. Output 1 is connected to the first spot light on the lowest level, output 2 to the second one,  

etc. Output 19 is connected to the last (19) spot. Output 25 is connected, looking from the bottom 

of the stairs, to the right handrail (running up), and output 24 to the left one (running down). Lamps 

generally have no polarity, so you should just follow the rule that the lights should be connected with 

each other and with the plus value, and the second pole of each lamp must be connected to the 

corresponding controller output.

If the staircase is smaller and there are no illuminated handrails, you can use exit No. 25 for 

example for ceiling lighting above the stairs (of course, if you have one). However, LED elements 

with 12V power must be used. Do not connect lighting powered by 230V!

The next diagram shows a solution where output 25 is connected to three 12V LED lights placed 

on the ceiling above the stairs. The controller will turn them on with the first step, and turn them  off 

about 2 seconds after the lighting of the last step turns off. Of course, you can use any other light 

source with the voltage of 12V, depending on the design of the stairs, instead  of the ceiling lamps.

12V spots connected to the controller

Содержание STX-1797

Страница 1: ...f stairs and after some time fades them out smoothly The controller is adapted to control MONO LED strips mounted in stair steps or LED points spots built into the wall above the steps The LED strip c...

Страница 2: ...mber of illuminated handrails 2 Supply voltage 12V Dimensions length 11cm width 9cm height 7 cm Mounting on T 35 rail the width of 6 modules Output capacity up to 5A per one output Running by short to...

Страница 3: ...he LED lighting is connected should be checked carefully Similarly the animation after the button BOT is pressed should be checked in this case the stairs lighting should take place downwards It is re...

Страница 4: ...lored bands RGB there is the dedicated STX 1793 controller The standard supply voltage is 12V The controller can also be connected to 24 V LED strips but because of the controller electronics the volt...

Страница 5: ...west level output 2 to the second higher etc The output 32 is connected looking from the bottom of the stairs to the right handrail running up and the output 31 to the left handrail running down All t...

Страница 6: ...the right handrail running up and output 24 to the left one running down Lamps generally have no polarity so you should just follow the rule that the lights should be connected with each other and wi...

Страница 7: ...lights should have a much larger cross section than the cables between the controller and individual LED strips Installation must be carried out very carefully and securely to avoid loosening of wires...

Страница 8: ...the controller inputs Low voltage sensors will almost certainly need a special adapter matching the sensor signal to requirements of the controller The following diagrams and descriptions explain how...

Страница 9: ...e same as the controller Their use helps with the installation Photo to the left shows our product STP 4811 a set of two relays in a single rail case T 35 This set makes it possible to separate 230 V...

Страница 10: ...of the Fresnel lens sho uld be covered with an opaque material If the motion sensor does not have a built in light sensor at least a small steady source of light over the sensor should be added to lig...

Страница 11: ...e of sensitivity adjustment as well as a removable bowl that can be screened to reduce the field of view It is equipped with a diode signaling the impulse of the sensor It can be powered from the same...

Страница 12: ...on the sensor connector It is recommended to use colored wires with a possibly small cross section eg a telephone cable harness Please note that any mistake in connecting wires especially power suppl...

Страница 13: ...13 www stairslight com Installation diagram 12V motion sensors connected to the controller...

Страница 14: ...se mezzanine but so it does not react to people walking up the stairs After detecting a person entering the stairs to the mezzanine the controller will immediately start the lighting of the whole stai...

Страница 15: ...s follows setting each parameter is indicated by a rapid flickering of the green LED and first step If during this flickering the SET button is pressed and held then depending on the parameter you wil...

Страница 16: ...from the bottom to the mezzanine To set the number of steps press and hold the SET button during the third flickering You should release the button after the right number of flicks Eg to set 8 steps...

Страница 17: ...portional to the time interval and is approximately 0 5 seconds per unit impulse This parameter is factory set to 0 minimum value which makes the next step is lightened immediately after the previous...

Страница 18: ...ong impulse often lasting dozens of seconds It can cause an incorrect operation of the controller eg a constant light In this case you can set a delayed start of the controller about 1 minute At that...