Description of parameters 

Flickering 1 – Count of stairs. 

The controller is factory-set for 15 steps. This can be changed with this parameter. The range is 

from 5 to 23 steps. To change the number of steps, press and hold the 

SET

 button during the first 

flickering. You should release the button after the right number of flicks. Eg., to set 18 steps, release 

the button after 18th flick.

Flickering 2 – Count of rails. 

The controller is factory-disabled for lighting the railing. You can turn on one or two rails. Note: 

two rails should be set only if in the entire staircase there  are handrails on both sides. In other cases, 

such as one handrail divided into two sections, set the operation to one handrail! Releasing the button 

after the first slow pulse sets the lighting for one rail, and letting go after the second pulse – sets 

the lighting for two rails. Releasing the button after the end of flickering and before the first pulse 

switches off the backlight railing.

Flickering 3 – Count of stairs to a mezzanine. 

The controller also can be used for a staircase with an entrance to a mezzanine. This case supports 

the third detector (or button) connected to the input No. 3. The controller is factory-set to no animation 

at the entrance to the mezzanine - turn on the whole staircase. However, you can start the animation 

consisting of successive lighting of stairs up and down from the mezzanine. You will need to set in 

this option, which is the number of stairs from the bottom to the mezzanine. To set the number of 

steps, press and hold the 

SET 

 button during the third flickering. You should release the button after 

the right number of flicks. Eg., to set 8 steps, release the button after 8th flick.To re-enable lighting up 

stairs upon entering mezzanine you must let go off the button immediately after the third flickering.

Flickering 4 – Staircase backlight. 

Steps backlighting is used to gently brighten the steps so they are easily visible, which gives a 

pleasant impression. There is no possibility of adjusting the backlight brightness. The backlight does 

not work with lamps without a dimming function (dimmable); in such a case it should be turned off. 

For this parameter (backlight on), releasing the button just after the flickering ends turns the backlight 

off, and releasing after the first pulse – turns it on.

Flickering 5 – Animation type. 

The controller has 3 different light animation programs (for upward direction): 

WAVE

 – stairs light 

up one after another, 

CASCADE

 – the light „jumps” fast from top to bottom, lighting up the steps, 

ELEVATOR – three lighted steps slowly „move” to the top of the staircase. When descending, the 

direction of the animation changes suitably. In the factory, the animation cycle is preset in the follo-

wing way: first 

WAVE

, then 

CASCADE

 and finally 

ELEVATOR

, and then the sequence is repeated. 

Releasing the button after the first pulse turns the program 1 (Wave), the second pulse turns on 

program 2 (Cascade), and releasing the button after the third pulse switches permanently to program 

No. 3 (Elevator). To return to the cycle animation function, the button should be let go immediately 

after the end of the flickering.

Содержание STX-1797

Страница 1: ...f stairs and after some time fades them out smoothly The controller is adapted to control MONO LED strips mounted in stair steps or LED points spots built into the wall above the steps The LED strip c...

Страница 2: ...mber of illuminated handrails 2 Supply voltage 12V Dimensions length 11cm width 9cm height 7 cm Mounting on T 35 rail the width of 6 modules Output capacity up to 5A per one output Running by short to...

Страница 3: ...he LED lighting is connected should be checked carefully Similarly the animation after the button BOT is pressed should be checked in this case the stairs lighting should take place downwards It is re...

Страница 4: ...lored bands RGB there is the dedicated STX 1793 controller The standard supply voltage is 12V The controller can also be connected to 24 V LED strips but because of the controller electronics the volt...

Страница 5: ...west level output 2 to the second higher etc The output 32 is connected looking from the bottom of the stairs to the right handrail running up and the output 31 to the left handrail running down All t...

Страница 6: ...the right handrail running up and output 24 to the left one running down Lamps generally have no polarity so you should just follow the rule that the lights should be connected with each other and wi...

Страница 7: ...lights should have a much larger cross section than the cables between the controller and individual LED strips Installation must be carried out very carefully and securely to avoid loosening of wires...

Страница 8: ...the controller inputs Low voltage sensors will almost certainly need a special adapter matching the sensor signal to requirements of the controller The following diagrams and descriptions explain how...

Страница 9: ...e same as the controller Their use helps with the installation Photo to the left shows our product STP 4811 a set of two relays in a single rail case T 35 This set makes it possible to separate 230 V...

Страница 10: ...of the Fresnel lens sho uld be covered with an opaque material If the motion sensor does not have a built in light sensor at least a small steady source of light over the sensor should be added to lig...

Страница 11: ...e of sensitivity adjustment as well as a removable bowl that can be screened to reduce the field of view It is equipped with a diode signaling the impulse of the sensor It can be powered from the same...

Страница 12: ...on the sensor connector It is recommended to use colored wires with a possibly small cross section eg a telephone cable harness Please note that any mistake in connecting wires especially power suppl...

Страница 13: ...13 www stairslight com Installation diagram 12V motion sensors connected to the controller...

Страница 14: ...se mezzanine but so it does not react to people walking up the stairs After detecting a person entering the stairs to the mezzanine the controller will immediately start the lighting of the whole stai...

Страница 15: ...s follows setting each parameter is indicated by a rapid flickering of the green LED and first step If during this flickering the SET button is pressed and held then depending on the parameter you wil...

Страница 16: ...from the bottom to the mezzanine To set the number of steps press and hold the SET button during the third flickering You should release the button after the right number of flicks Eg to set 8 steps...

Страница 17: ...portional to the time interval and is approximately 0 5 seconds per unit impulse This parameter is factory set to 0 minimum value which makes the next step is lightened immediately after the previous...

Страница 18: ...ong impulse often lasting dozens of seconds It can cause an incorrect operation of the controller eg a constant light In this case you can set a delayed start of the controller about 1 minute At that...

Отзывы: