Adjusting the controller
Setting the parameters should be performed only when strictly necessary, after reading the
following description carefully.
To start the parameter setting mode, press and hold the
SET
button until the green
LED
fades
out. Release the button to go on to the controller parameter setting mode. A few seconds flickering
of the
LED
(and first step) corresponds to each parameter. You can set or change 12 parameters,
and therefore there will be twelve consecutive flickers of the
LED
. In order to facilitate counting them,
a marker is inserted after every five flickers – a two second
LED
constant light. To select a specific
parameter to be changed, you should count each flicker and then, after a suitable number of flickers,
press the
SET
button. If you do not want to change a parameter, skip the flickering without pressing
the button. If at the parameter setting mode the
SET
button is not pressed, none of the parameters
will change.
The principle of setting the parameters is as follows: setting each parameter is indicated by a
rapid flickering of the green
LED
(and first step). If during this flickering the
SET
button is pressed
and held, then, depending on the parameter, you will see from one to several dozens of slow
LED
pulsees. Setting the parameter takes place after a release of the button after the desired number of
pulsees or just after the end of the flickering. During the flickering, if the SETUP button is not pressed,
after a short time of the
LED
fading out, flickering of the next parameter will appear and so on until
the end of the setting mode. If the given flicker is omitted, the corresponding parameter will not be
changed. This allows you to set only one parameter, without any of the others. Notice: if the
SET
button is pressed during the flickering and released immediately after it, but before the first pulse,
the parameter will return to the factory setting.
After setting the selected parameter, the controller immediately returns to a stand-by state, waiting
for a signal from pulse sensors or push buttons. There are no flickers for other parameters. To set