Pipe Size

Pipe O.D. (in.)

Pipe I.D. (in.)

K Value

Offset

Suggested 

Operating Range 

(gpm)

14 inch Sch 10S

14 .00

13 .500

122 .307

0 .391

200…6000

Sch 20

14 .00

13 .375

120 .216

0 .388

200…6000

Std . Wt ., Sch 30

14 .00

13 .250

118 .151

0 .385

200…6000

Sch 40

14 .00

13 .124

116 .096

0 .382

200…6000

Sch 60

14 .00

12 .814

111 .148

0 .376

200…6000

Extra Strong

14 .00

13 .00

114 .098

0 .33

200…6000

Sch 80

14 .00

12 .50

106 .299

0 .369

200…6000

16 inch Sch 10S

16 .00

15 .500

159 .243

0 .44

300…9000

Sch 20

16 .00

15 .375

156 .742

0 .436

300…9000

Std . Wt ., Sch 30

16 .00

15 .250

154 .267

0 .433

300…9000

Sch 60

16 .00

14 .688

143 .456

0 .419

300…9000

Extra Strong, Sch 40

16 .00

15 .000

149 .394

0 .427

300…9000

Sch 80

16 .00

14 .314

136 .548

0 .41

300…9000

18 inch Sch 10S

18 .00

17 .500

202 .739

0 .498

350…10,000

Sch 20

18 .00

17 .375

199 .828

0 .494

350…10,000

Sch 30

18 .00

17 .124

194 .061

0 .486

350…10,000

Std . Wt .

18 .00

17 .250

196 .943

0 .49

350…10,000

Sch 40

18 .00

16 .876

188 .464

0 .479

350…10,000

Sch 60

18 .00

16 .500

180 .171

0 .469

350…10,000

Extra Strong

18 .00

17 .000

191 .25

0 .482

350…10,000

Sch 80

18 .00

16 .126

172 .152

0 .457

350…10,000

20 inch Std . Wt ., Sch 20

20 .00

19 .25

246 .179

0 .555

400…12,000

Sch 40

20 .00

18 .812

234 .836

0 .540

400…12,000

Extra Strong, Sch 30

20 .00

19 .000

239 .666

0 .547

400…12,000

Sch 80

20 .00

17 .938

213 .14

0 .511

400…12,000

22 inch Std . Wt ., Sch 20

22 .00

21 .25

301 .975

0 .621

500…15,000

Extra Strong, Sch 30

22 .00

21 .00

294 .642

0 .616

500…15,000

Sch 80

22 .00

19 .75

259 .513

0 .573

500…15,000

24 inch Std . Wt ., Sch 20

24 .00

23 .25

364 .331

0 .666

600…18,000

Extra Strong

24 .00

23 .00

356 .178

0 .660

600…18,000

Sch 40

24 .00

22 .624

344 .109

0 .652

600…18,000

Sch 80

24 .00

21 .562

311 .271

0 .628

600…18,000

26 inch Sch 10

26 .00

25 .376

437 .809

0 .719

700…21,000

Std . Wt .

26 .00

25 .25

433 .247

0 .716

700…21,000

Sch 20, Extra Strong

26 .00

25 .00

424 .274

0 .709

700…21,000

28 inch Sch 10

28 .00

27 .376

513 .698

0 .774

900…23,000

Std . Wt .

28 .00

27 .25

508 .723

0 .770

900…23,000

Extra Strong, Sch 20

28 .00

27 .00

498 .930

0 .763

900…23,000

30 inch Sch 10

30 .00

29 .376

596 .147

0 .833

1000…30,000

Std . Wt .

30 .00

29 .25

590 .759

0 .829

1000…30,000

Sch 20, Extra Strong

30 .00

29 .00

580 .146

0 .822

1000…30,000

32 inch Sch 10

32 .00

31 .376

685 .156

0 .897

1200…35,000

Std . Wt .

32 .00

31 .25

679 .355

0 .893

1200…35,000

Sch 20, Extra Strong

32 .00

31 .00

667 .922

0 .885

1200…35,000

Sch 40

32 .00

30 .624

650 .919

0 .873

1200…35,000

34 inch Sch 10

34 .00

33 .312

777 .566

0 .964

1300…40,000

Std . Wt .

34 .00

33 .25

774 .511

0 .962

1300…40,000

Extra Strong, Sch 20

34 .00

33 .00

762 .258

0 .953

1300…40,000

Sch 40

34 .00

32 .624

744 .022

0 .940

1300…40,000

36 inch Sch 10

36 .00

35 .376

882 .855

1 .040

1500…45,000

Std . Wt .

36 .00

35 .25

876 .227

1 .035

1500…45,000

Sch 20, Extra Strong

36 .00

35 .00

863 .154

1 .025

1500…45,000

Sch 40

36 .00

34 .50

837 .315

1 .007

1500…45,000

Calibration

Page 15 

February 2018

SEN-UM-01635-EN-11

Содержание 220 Series

Страница 1: ...Flow Sensors Insertion Style Flow Sensors Series 220 225 226 SEN UM 01635 EN 11 February 2018 User Manual...

Страница 2: ...is Depressurized and Drained 7 Installation into a Pressurized Pipeline 7 Electrical Installation 10 Standard Sensors 10 IR Sensors 10 High Temperature Sensors 11 Electrical Installation Safety 11 Ca...

Страница 3: ...y dependent on proper location in the piping system Irregular flow velocity profiles caused by valves fittings and pipe bends can lead to inaccurate overall flow rate indications although local flow v...

Страница 4: ...or inserted 1 1 2 inches 38 mm into the pipe flow To determine the proper insertion depth follow these steps 1 Apply anti seize thread lubricant supplied with the sensor to the threaded studs of the m...

Страница 5: ...S 2 As a backup to the flow arrow label there is a small hole next to the larger sight hole of the upstream side With a 3 32 inch Allen wrench tighten the positioning collar set screws 3 Double check...

Страница 6: ...the hex nuts 14 7 8 inches 378 mm minus the thickness of the pipe from the outside diameter of the pipe For example measure the wall thickness of the pipe from the coupon removed when the 1 7 8 inch...

Страница 7: ...pressure that may have built up b Fully open the isolation valve c Push the sensor sleeve into the pipe with a slight twisting motion d Guide the sensor collar holes over the three hex adapter studs...

Страница 8: ...valve on the hex mounting adapter to relieve the pressure resulting from the flow sensor sleeve insertion 7 Carefully hand insert the hot tap flow sensor sleeve assembly into the hex mounting adapter...

Страница 9: ...of the positioning collar with a 3 32 inch Allen wrench 19 Align the sensor sight holes along the pipe axis using the alignment rod from the sensor installation kit Make sure the flow label arrow on t...

Страница 10: ...O NOT remove the plastic caps from the sensor leads until ready to splice 1 Use a twisted pair cable suitable for direct burial to connect the sensor to the transmitter monitor or controller Multi pai...

Страница 11: ...afe when installed in conformance with Badger Meter installation drawing 06 480 002 Figure 5 as specified on the blue label identifying an intrinsically safe sensor Entity approval implies that only t...

Страница 12: ...OF BADGER METER TOLERANCE ON 4 PLACE DIMENSIONS 0025 0635 THIS DRAWING TO BE USED WITH CAD MODEL WHEN SUPPLIED BY BADGER METER FOR COMPLETE PRODUCT DEFINITION PER ANSI Y14 41 2003 DRAWING AND TOLERANC...

Страница 13: ...mns 4 and 5 The K value and Offset that should be used in our frequency equation Freq Gpm K Offset This equation describes the frequency of the output signal of all Badger Meter flow sensors By substi...

Страница 14: ...3 21 068 0 256 50 1500 8 inch Sch 10S 8 625 8 329 43 914 0 286 80 2500 Sch 20 8 625 8 125 41 653 0 283 80 2500 Sch 30 8 625 8 071 41 063 0 283 80 2500 Std Wt Sch 40 8 625 7 981 40 086 0 281 80 2500 Sc...

Страница 15: ...511 400 12 000 22 inch Std Wt Sch 20 22 00 21 25 301 975 0 621 500 15 000 Extra Strong Sch 30 22 00 21 00 294 642 0 616 500 15 000 Sch 80 22 00 19 75 259 513 0 573 500 15 000 24 inch Std Wt Sch 20 24...

Страница 16: ...letely out The impeller assembly will now be free and will drop out 5 Inspect the shaft and bearings for wear and replace as necessary 6 See Figure 5 To reinstall position the impeller in the cavity o...

Страница 17: ...terminals ON and OFF repeatedly allows the display to respond by trying to calculate a flow rate for the frequency of your shorting action If the display does not show a change from 0 00 it indicates...

Страница 18: ...100 psi 68 F Recommended Design Flow Range 0 5 30 ft sec Initial detection below 0 3 ft sec Accuracy 1 0 of full scale over recommended design flow range Repeatability 0 3 of full scale over recommend...

Страница 19: ...User Manual INTENTIONAL BLANK PAGE Page 19 February 2018 SEN UM 01635 EN 11...

Страница 20: ...Meter Slovakia s r o Racianska 109 B 831 02 Bratislava Slovakia 421 2 44 63 83 01 Asia Pacific Badger Meter 80 Marine Parade Rd 21 06 Parkway Parade Singapore 449269 65 63464836 China Badger Meter 7 1...

Отзывы: