18
Flame goes out
High or gusting winds
Do not use grill in high winds
Low on LP Gas
Exchange, refill or replace LP gas tank
Overfilling prevention device may have been
activated
Refer to “Sudden drop in gas flow or reduced flame height” (see above)
Flare-up
Grease buildup
Remove and clean all grill parts per “Cleaning and Care” section
Excess fat in meat
Trim fat from meat before grilling
Excessive cooking temperature
Adjust to lower cooking temperature
Persistent grease
fire
Grease trapped by food buildup around burner
system
1 . Turn control knobs to “ OFF”
2 . Turn LP gas tank valve to “CLOSED”
3 . Leave lid in closed position and let fire burn out
4 . After grill cools, remove and clean all parts per “Cleaning and Care”
section
Flashback (fire in
burner tube(s))
Burner and/or burner/venturi tube are blocked
Clean burners and/or burner/venturi tube
Inside of lid is
peeling (like
paint peeling)
Baked on grease buildup has turned to carbon
and is flaking off .
Clean all grill parts per “Cleaning and Care” section .
Troubleshooting (Continued)