16
Figure 6
Burner Flame Conditions
Use this chart to see if your burners need to be
cleaned .
1-2 in. /
25.4 - 50.8 mm
Normal:
Soft blue flames with yellow
tips between 1 in . - 2 in . height .
Needs cleaning:
Noisy with hard
blue flames .
Has to be replaced:
Wavy with
yellow flames .
Cleaning Surfaces
1 . Wipe surfaces clean with mild dishwashing detergent or baking soda mixed with water .
2 . For stubborn surfaces, use a citrus-based degreaser and a nylon scrubbing brush .
3 . Rinse clean with water .
4 . Allow to air dry .
Before Storing
1 . Turn LP gas tank valve to “CLOSED .”
2 . Turn all control knobs clockwise to the “ OFF” position .
Note: A “poof” sound is normal as the last of the gas is burned .
3 . Disconnect LP gas tank per “Disconnecting LP Gas Tank” section .
4 . Clean all surfaces .
5 . Lightly coat the burner(s) and cooking grid(s) with cooking oil to prevent excess rusting .
6 . If storing the grill indoors, disconnect the LP tank per “Disconnecting LP Gas Tank” section .
7 . Place the protective cap cover on the LP tank and store the tank outdoors in a well-ventilated area out of direct sunlight .
8 . If storing the grill indoors, cover the grill and store in a cool dry place .
9 . If storing the grill outdoors, cover the grill with a grill cover for protection from the weather .
Cleaning and Care (Continued)
Cleaning Main Burner
1 . Turn LP gas tank valve to “CLOSED .”
2 . Turn all control knobs clockwise to the “ OFF” position .
Note: A “poof” sound is normal as the last of the gas is burned .
3 . Disconnect LP gas tank per “Disconnecting LP Gas Tank” section .
4 . Remove cooking grids and heat plates .
5 . Remove burners by removing the fasteners, which secure the burners to the grill bottom .
6 . Lift burners up and away from gas valve orifice .
7 . Disconnect wire from spark electrode .
8 . Clean venturi of each burner with small bottle brush or compressed air .
9 . Remove all food residue and dirt from burner surface .
10 . Clean any clogged ports with a stiff wire (such as an opened paper clip
11 . Inspect burners for any damage (cracks or holes) . If damage is found, replace with new
burner(s) from manufacturer
12 . Re-install burner(s) . Checking to insure that gas valve orifice is correctly positioned inside
each burner/venturi tube . Also, check position of spark electrode .
13 . Replace heat plate(s) and cooking grid(s) .
14 . Connect LP gas tank per “Installing LP Gas Tank” section .
15 . Perform leak test per “Checking for Leaks” section .