Section 7. Troubleshooting
Symptom
Possible Cause(s)
Green and Red light
off
•
Check power supply. Check wiring.
•
MGS-150 was possibly damaged in
transit. Check by installing another
MGS-150 to confirm the fault.
Red light on, green led
off (indicates a fault)
•
Sensor may be disconnected from
printed circuit board. Check to see
sensor is properly inserted into board.
•
The sensor has been damaged or has
reached the end of life and needs to be
exchanged. Contact Bacharach for
instructions and support.
Alarms in the absence
of a leak
•
Try setting an alarm delay.
•
Perform a bump test to ensure proper
operation.