![Bacharach High Flow Sampler Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/bacharach/high-flow-sampler/high-flow-sampler_instructions-manual_3386771049.webp)
Hi Flow
Sampler
Maintenance
Instruction 0055-9017
49
4.4.2 Leak-Gas Sensor Filter
The leak-gas sensor filter is located inside the flow block of the leak-gas sensor
assembly. See Figure 4-4.
Equipment Required:
•
Medium Phillips Head Screwdriver
•
Replacement Filter (P/N 0055-0045)
Procedure:
1.
Remove the cover per Section 4.3.
2.
Remove tubing from inlet of sensor assembly.
3.
Unscrew the filter chamber’s gas inlet fitting; then pull out old filter and discard.
4.
Insert new filter; reinstall the inlet fitting; then reinstall tubing.
5.
Replace the cover that was removed in Step 1.
4.4.3 Background-Gas Sensor Filter
The background-gas sensor filter is located inside the flow block of the background-gas
sensor assembly. See Figure 4-4.
Replace filter as previously described for the leak-gas sensor filter.
Figure
4-4
. Leak Gas & Background Gas Sensor Filter Replacement