background image

16

Manual: MaxBright

®

 II Binoviewer

Assembly with 2" Newtonian 1 .7x Glasspath Corrector

®

 

As described before, you need to replace the 
T-2 counter nut with the Zeiss microbayonet. 
The 1.7x glasspath corrector is then attached to 
the binoviewer instead of the TQC quickchang-
er. The TQC is not necessary for this setup.

The 2" Newtonian glasspath corrector 

# 2456300

 provides you a focus gain of approx. 

80 mm. It is the only chance for many Newto-
nian telescopes to reach focus without moving 
the main mirror.

Assembly with the 2" Glasspath Corrector 1 .8x for Refractors and SC's

As described before, attach the Zeiss microbayonet to the MaxBright II instead of 
the T-2 counter nut. Attach the Glasspath Corrector to one side of the T-2 Maxbright 
Mirror 

# 2456100

  and the TQC QuickChanger to the other side. For the GC to work 

correctly, the distances have to match exactly, which is why you must use the T-2 
Maxbright Mirror and no other star diagonal. 

Then put the 2" 1.8x Glasspath Corrector 

# 2456305

 with 

the attached star diagonal into the 2" eyepiece holder of 
your telescope and secure it. Then you can attach 
the binoviewer at the TQC QuickChanger and 
insert the eyepieces.

PLEASE NOTE:

 This GC is inserted deeply into 

the telescope, therefore it can only be used with 
Schmidt-Cassegrains with a sufficiently large baffle, or at 
telescopes without correctors close to the visual back. It can 
not be used with Petzval, EdgeHD or some Maksutov-telescopes 
with corrector lenses close to the eyepiece holder.

Assembly with 2" Star Diagonals

With Glasspath Correctors 1,25x 

# 2456314  (Z), 

1,7x 

# 2456316  (Z)

 or 2,6x 

# 2456317

To use a 2" star diagonal, you first have to remove the 2" eyepiece clamp as described 
on page 7, then screw the SC/T-2-adapter 

#1508035

 into the housing. 

Next place the plastic spacer ring above the thread of the glasspath corrector. Now 
insert the glasspath corrector into the T-2/SC-adapter. It is held safely in place as soon 
as you attach the quickchanger or the binoviewer.

Exception:

 The two glasspath correctors 1,25x 

# 2456314Z

 and 1,7x 

# 2456316Z

 for 

Zeiss micobayonet are mounted in the ring dovetail as described before.
The 2" ClickLock

®

-clamps of our 2" star diagonals and the Herschel Wedge (see 

below) can be removed. For this, you need to remove the small screws, as shown here 
for the BBHS

®

 mirror diagonal 

# 2456115

, or in the case of the Herschel, you need to 

2" 1.7x GC 

# 2456300 

at 

MaxBright

®

 II Binoviewer

2" 1.8x GC 

# 2456305 

at the  

MaxBright

®

 II

Содержание MAXBRIGHT II

Страница 1: ...e you with a lifetime of amazing views To ensure optimal performance please read this instruction manual before using your binoviewer BAADER PLANETARIUM ZurSternwarte4 D 82291Mammendorf Tel 49 0 8145...

Страница 2: ...Diagonal 12 Option 2 Assembly with a 1 or 2 Nosepiece without Star Diagonal 13 Assembly with Zeiss Microbayonet 14 Option 1 Assembly with a T 2 Star Diagonal 14 Option 2 Assembly without Star Diagona...

Страница 3: ...remove colour aberration which will occur because of the long light path through the glass prisms in the binoviewer if it is used with fast telescopes with focal ratios between f 4 and f 7 because of...

Страница 4: ...ble T 2 Coupling Nut pre mounted 3 Zeiss microbayonet dovetail ring 4 Spanner tool to fix T 2 adapter or Zeiss Microbayonet to the bino viewer 5 ABS hard top case with compartment for a T 2 star diago...

Страница 5: ...20 mm 2456316 2456316Z 1 7x ca 35 mm 2456317 2 6x ca 65 mm 2456300 1 7x ca 80 mm 2 Glasspath Corrector for Newton to attach to the Zeiss microbayonet 2456305 1 8x ca 80 mm 2 Glasspath Corrector for R...

Страница 6: ...diagonal 36 mm Zeiss Prism 38 5 mm wit BBHS coating 2456130 T 2 90 Baader Astro Amici Prism with 48 mm BBHS coating for upright images 2456103 Baader T 2 BBHS star diagonal mirror 43 mm 2458055 FlipM...

Страница 7: ...m diagonal with 2 ClickLock clamp 2456117 Part Number Name Optical Length 2956100 Baader 2 ClickLock Mirror Diagonal 71 5 mm 2456115 Baader 2 BBHS Mirror Diagonal 71 5 mm 2456117 Baader 2 BBHS Prism D...

Страница 8: ...bodies small locking screws and a generally lightweight construction are inadequate to safely hold heavy accessories like a binoviewer Unfortunately it s quite common to hear about heavy and expensive...

Страница 9: ...iameter for example the Pentax XW you may have problems reaching the correct separation between the two eyepieces if the interpupillary distance between your eyes is less than 60 mm For observing the...

Страница 10: ...Universal Zoom Mark IV eyepieces are made so that they provide the best sharpness and the largest field of view at the highest magnification Simple zoom eyepieces are designed the other way round Tha...

Страница 11: ...an object close the right eye and look into the left eyepiece Using the telescope s focus mechanism adjust until the image is sharp 3 Close the left eye and with the right eye look into the right eye...

Страница 12: ...you simply screw one of the GCs 2456314 2456316 or 2456317 into the star diagonal without the centering plastic ring which is included with the glasspath corrector Our star diagonals provide a matchi...

Страница 13: ...with the glass path corrector to the binoviewer Rotate the counter nut until the nosepiece holds tight 4 Now put the binoviewer into the focuser of your telescope and secure it 5 Remove the dust cover...

Страница 14: ...o 1 25x and 1 7x glasspath correctors are moun ted into the dovetail at the binoviewer The 2 6x glasspath corrector is inserted into the T 2 star diagonals as shown here 2 6x GC 1 25x 1 7x GC Remove t...

Страница 15: ...r with several telescopes The two glasspath correctors with factor 1 25x and 1 7x can be screwed into the ring dovetail as described for option 1 Then you can use the TQC quickchanger 2456313A to conn...

Страница 16: ...he TQC QuickChanger and insert the eyepieces PLEASE NOTE This GC is inserted deeply into the telescope therefore it can only be used with Schmidt Cassegrains with a sufficiently large baffle or at tel...

Страница 17: ...to permit safe high resolution observation and imaging of the solar photosphere As the Herschel Solar Prism does not have T 2 threads on the top a T 2 2 adapter ring 1508035 is required Inserting the...

Страница 18: ...crewed directly into the binoviewer without the black plastic ring The 2 6 glasspath corrector must be put into the SC T 2 adapter 1508035 together with the black spacer ring It is locked in place by...

Страница 19: ...2 very compact and protected from accidental removal To do so you have to remove the T 2 counter nut or the Zeiss microbayonet The shortest possible adaptation can be achieved with the prism diagonal...

Страница 20: ...the focal point well past the focuser surface a larger secondary mirror would be required or at least moving the primary mirror up the tube which of course creates its own issues too This increases th...

Страница 21: ...lengths are approximate values allow for some variation e g for diopter adjustment Some telescopes don t have enough back focus for any of our glasspath correctors Try to avoid 2 star diagonals becau...

Страница 22: ...selecting the matching Glasspath Correctors you need to measure the back fo cus of your telescope first as described in the previous chapter Table 1 on the previ ous page then tells you which compensa...

Страница 23: ...lly the glass surfaces of your binoview er will not require anything more than a burst of clean air from a blower bulb in order to remove dust Avoid touching the optical window lens or the prisms insi...

Страница 24: ...5 www baader planetarium com kontakt baader planetarium de www celestron de G M B H 2020 Baader Planetarium All Rights reserved Products or instructions may change without notice or obligation Images...

Отзывы: