Primary coil (primary hob)
The primary coil has 2 power levels in addition to the 3 heat-retaining levels and the 8 power
steps.
Power level 1
Power level 1 [P] provides permanent power consumption of 2.3 kW under certain circumstan-
ces (scenarios 1 and 2).
Set the primary coil rotary knob to the P position.
The rotary knob will lock automatically. The following symbol is displayed on the associated
7-segment display:
Scenario 1:
Primary coil power level 1 [P] is active and secondary coil is switched on.
The secondary coil can be switched on up to power step 7.
Scenario 2:
Secondary coil is active at power step 8. Primary coil power level 1 [P] is switched on.
The secondary coil is automatically switched down to power step 7.
Power level 2
Power level 2 [P] provides power consumption of 2.8 kW for a maximum of ten minutes under
certain circumstances.
9
The primary coil rotary knob is set to position P (power level 1).
Turn the rotary knob right for about 1–2 seconds until it reaches the spring-loaded stop at
power level 2 [P].
An audible signal sounds and the following symbol is displayed in the assigned 7-segment dis-
play:
)
The knob springs back to power level 1. Power level 2 remains active and is shown by the
symbol in the 7-segment display.
)
If power level 2 is active, only power steps (not heat-retaining levels) can be activated in the
secondary coil.
Scenario 1:
Primary coil power level 2 [P] is active and secondary coil is switched on.
The secondary coil can be switched on up to power step 5. After automatic reducing (max.
10 min.) power level 2 [P] to power level 1 [P], the secondary coil can be increased to power
step 7. To do so, the secondary coil rotary knob must first be reset to power step 5 (or lower).
The secondary coil can then be raised to a maximum power step of 7.