background image

Typ

Colour

Part nr.

LC-Mini 120

white

91051

LC-Mini 120

black

91071

LC-Mini 180

white

91052

LC-Mini 180

black

91072

Accessory:

RC-Suppressor

10880

15. Article / Part nr. / Accessory

14. 

Technical data

Power supply:

230 V~ 

±

10 %

Detection area:

LC-Mini 120

120°

LC-Mini 180

180°

Range of coverage in m:

max. 10 m when walking across (tangential

)

Degree of protection/class:

IP 44 / II / 

Dimension:

L 80 x B 55 x H 70 mm

Ambiente temperature:

-25°C to +50°C

Package:

Housing UV- and shock-resistant Polycarbonate

Chanel 1 for light control
Contact load: 

 

1000 W, cos

ƙ

= 1, 

μ

-Contact

Time-settings:

4 s - 10 min.

Brightness value:

2 - 1000 Lux

Declaration of Conformity: 

The product complies with the low voltage 

recommendation 2006/95/EC/ and the EMV 

recommendation 2004/108/EC.

12. Dimensions (mm)

M

A

N 6

93

6 – 0

10

61

1-

1

11. Wiring diagrams

N

L

N

L

L‘

C 1

E 1

L

N

E 1

S 1

RC

N

L

L‘

C 1

N

N

L

L

L‘

C 1

E 1

T 7

L

L

L

C 1

C 1

L‘

L‘

N

N

N

E 1

L

L

L

L‘

N

N

N

E 1

T 1

T 2

30 s - 

10 min.

4

3

13. Trouble Shooting-Practical hints

1. Lamp does not light up
Cause

- Action

Lamp is defective

- Replace light bulb

.

No mains connection

- Check mains fuse

.

Switching threshold of the twilight switch is not 
correct

- Accordingly adjust sensitivity of twilight 

switch via the setting dial.

Detection area not set correctly
Set detection area correctly.
Unit mounted too high

- Mount at recommended height (2.50 m)

PIR detector lens obstructed by dirt or other 
objects

- Clean lens or remove objects

2. Delayed lamp activation

Mounted too high

0RXQWDWKHLJKWVWDWHGLQVSHFLÀFDWLRQ

(2.5 m)

Only direct in-line approach of detector is 
possible 

- Mount detector in such a way that a 

sideways approach is also detected.

3. Lamp stays on continuously

Continuous thermal movement within detection 
area 

- Remove the heat source out of the detection 

area.

Check the correct functioning of the detector 
in fully covering the lens (lights should go out 
after a certain time-delay).

Motion detector is switched parallel to a switch 
that enables direct manual switching on 

- Mind the correct connection of the switch.

4. Light source remains on for long periods 

when no persons are present

3HUPDQHQWLQÁXHQFHIURPKHDWVRXUFHVZLWKLQ

detection area (trees, shrubs when blown by 
the wind, presence of animals like cats and 
dogs in the detection area)

- Reduce detection area of the detector in 

turning the detector head downward or 
cover parts using the enclosed covers.

Direct sunlight radiation into detector lens

- Shelter lens from direct sunlight.

Detector mounted above extractor fan

- Change mounting place of the detector.

5. Limitation of range (not up to the minimum 

VSHFLÀFDWLRQ

Mounting height is not optimal

- Accordingly change mounting height 

(2.50 m).

Persons only move directly towards 

the detector

- Mount detector in such a way that a 

sideways 

approach is also detected.

Steep terrains

- Adjust spherical head accordingly.

6. No reaction to vehicles

Vehicle not warmed up
Vehicle is well insulated (by silencing equip-
ment)

Standard mode with 1-channel motion detector

Standard mode with 1-channel motion detector with

permanent light function

Standard mode with 1-channel motion 

detector with NC pushbutton

Parallel connection with 1-channel motion detectors

Standard mode with 1-channel motion detector 

(e.g. stairs)

optional:

S1 =

switch for permanent light

RC = 

RC-suppression kit if required

T 1 = NC button

Manual switching addition-

ally possible (press opener 

approx. 2 sec.).

The position of the poten-

tiometers should not be 

on “test” or “sun”. If so, 

the pre-set time and safety 

values get lost.

38

7

41

10

7

48

22

58

22

L

N

L’

Отзывы: