LUXOMAT
®
LC-Mini 120 / 180
GB
Installation and Operation Instruction motion detector
B.E.G.
–
LUXOMAT
®
LC-Mini 120 and LC-Mini 180
1. Mounting preparations
1)
Caution: have all work involving the
230 V mains supply carried out by a
qualified electrician! Before starting
disconnect the mains! Please be aware,
that the LUXOMAT
®
LC-Mini 120/180 is
not suitable as an intrusion detector, since
it is not equipped with a tamper contact.
2) Socket base corner mounting
Important:
The
LUXOMAT
®
LC-Mini
120/180 has to be mounted in such a way,
that the adjusting elements / rotary regulators
are always pointed downward.
1
2. Mounting types
1) Wall mounting
1
4. Inserting of the connection cable
1) Connection cable from top down
2) Terminal markings
8. Putting into operation / Settings
Follow-up time
4 sec. ...10 min.
Lux value
Night operation...Dusk...Day operation
(Day operation: light sensor inactive, switching at
any brightness value)
Self test cycle
After mounting and connecting the 230 VAC supply
voltage, the LC-Mini 120 / 180 goes through a self
testing unit of 60 seconds. Then the unit is ready for
operation and the settings can be made manually
or with remote control.
3. Plug-in socket
Mount the plug-in socket with two screws and
the enclosed seal rings on a firm base.
(Pay attention to inserting of the connection
cable, see point 4)
5. Connection
By swinging the sensor head horizontally
(ca. ±45°) and vertically (ca. ±15°) the
detection area can be changed.
2
6. Sensor head optics
7. Exclude sources of interference
9. Range of Coverage
walking towards
walking across
1
2
walking towards
walking across
1
2
1) If possible mount unit on a safe place
(wall or ceiling mount)
10. Mounting place
1
2
2) Influence of weather reduces the lifetime of
the unit. Please take care to mount correctly.
3
> 1m
4
3) Minimum distance to switched lighting,
frontally or laterally to device: 1 m
4) Never mount the connected lights below the
motion detector!
If necessary, the lens segment(s) corresponds to
unwanted detection zones may be masked with
WKHHQFORVHGFRYHUVWRUHGXFHWKHÀHOGRIYLVLRQ
L
N
L’
L
N
L’
Cover
L
N
L’
4
sec
20
50
1.2
10
min
6
1000
40
10
2 Lux
130
1000
40
10
2 Lux
130
4
sec
20
50
1.2
10
min
6
2
1
2
1
1) Connecting cable from top down
and behind
2) Terminal markings