background image

AB-7358-U 

Parts Identification 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 3.  Parts identification 

 

Hook to remove the case

from the base plate

Base plate

Case 

Face plate 

Insertion guide (female)

LCD 

Insertion guide (male)

Содержание QY5010S1000

Страница 1: ...513X and the valve position at one time Installable 164 ft 50 m away from Model FVY513X Display panel is connected to Model FVY513X with AWG 22 0 3 mm 4 core cable and max cable length is 164 ft 50 m...

Страница 2: ...ion For example the sign on the left notifies that disassembly is prohibited Instructs users to carry out a specific obligatory action to prevent possible danger The symbol inside d graphically indica...

Страница 3: ...se model number of Display Panel for Model FVY513X S1000S 001 Power supplied from ACTIVAL Flow Measurement and Control Valve standalone model Model FVY513X Specifications Item Specification Power supp...

Страница 4: ...lies with the following Electromagnetic Compatibility EMC EMC EN61326 1 Class A Table 2 For use in an industrial electromagnetic environment Dimensions Outside dimensions Figure 1 Outside dimensions M...

Страница 5: ...AB 7358 U 5 Parts Identification Figure 3 Parts identification Hook to remove the case from the base plate Base plate Case Face plate Insertion guide female LCD Insertion guide male...

Страница 6: ...160 psig Model FVY513E 0 to 320 psig 3 Q Actual flow 0 000 to 999 9 GPM 4 T1 Coil inlet temperature 14 to 212 F 5 T2 Coil outlet temperature 14 to 212 F Opening Valve position indicated in a bar grap...

Страница 7: ...to go back to the analog values display screen Note No button operation for continuous 10 minutes on the parameter setting screen will automatically switch from the parameter setting screen to the ana...

Страница 8: ...te and insert stripped lead wires to each terminal Terminals arrangement Figure 7 Sheath strip length Terminal number Type Lead wire color 1 12 V DC Red RED 2 0 V Black BLK 3 AP bus White WHT 4 AP bus...

Страница 9: ...se plate terminals out of the base plate through the base plate conduit on the bottom right and mount the base plate on the mounting location with the two M4 tapping screws accessory of Display Panel...

Страница 10: ...is generally installed on a visible position such as on a wall in a machine room or on a control panel cabinet However it may possibly be installed outdoors or in a ceiling In such a case install the...

Страница 11: ...the cable to Model FVY513X refer to Specification Installation of Model FVY513X AB 7350 U ACTIVAL Flow Measurement and Control Valve Standalone Model Models FVY5137J PN10 GG 20 AB 7354 U ACTIVAL Flow...

Страница 12: ...AB 7358 U ACTIVAL is a trademark of Azbil Corporation in Japan or in other countries Rev 3 0 Jun 2016 AB 7358 U 12...

Отзывы: