Chapter 5. SETTING AND OPERATION
■
Parameter setup
●
Setup method
(1) Push and hold the
[mode]
key 2 seconds or more in the normal indication mode.
The device enters function setup mode. Again press and hold the
[mode]
key 2
seconds or more. The
MCF
enters parameter setup mode.
(2) Move to the desired parameter by pushing
[
]
or
[
]
, and then press
[enter]
.
>> The current setting is indicated with the rightmost digit blinking.
(3) Push the
[mode]
key, and the left digit will blink.
(4) Use the
[
]
or
[
]
keys to increase or decrease the numeric value of the blink-
ing digit. Set the desired numerical value for each digit.
(5) When the desired value is set, press the
[enter]
key.
>> The setting is changed.
(6) Repeat steps (2) to (5) if you want to continue setup.
(7) To exit setup, while the parameter is displayed press and hold the
[mode]
key 2
seconds or more. The
MCF
returns to normal indication mode.
Note. If there is no key operation for 30 seconds or more, processing stops and the
display turns off. Since the mode will revert to the normal indication mode
when the display turns on again, as necessary, return to step (1) to begin the
interrupted setup again.
Blinking
Blinking
[mode] key
Example of parameter display
Sample display during setup
[enter] key
[enter] key
Parameter
selection
[enter] key
During
setup
After
setup
[mode] key
2s or more
Normal indication
(
Instantaneous flow rate
/
Integrated flow display/
No-display mode
)