CAUTION
If the safety shutoff has been activated, check all of the items on the
checklists in Chapter 3, ADJUSTMENTS FOR TRIAL OPERATION
before restarting the equipment.
Check the flame current at least once per month. Doing so can prevent
shutdowns caused by a weak flame current signal.
This device has an operating life. Assuming that the operating life of
the combustion equipment used with this device is longer, be sure to
do periodic maintenance and replacement of this device.
In the event that this device is replaced, do all of the checks listed in
Chapter 3, ADJUSTMENTS FOR TRIAL OPERATION.
When doing a maintenance inspection of the burner, be sure to do the
pilot turndown test. Inspection must be done at least once a year.
Conduct periodic inspections in accordance with the user's manual of
the equipment manufacturer.
When cleaning the burner, clean the flame detector as well.
Do not transport this device while it is mounted on a DIN rail. Remove
it from the subbase and pack it in its original box. If it is transported
while on a DIN rail, it might fall off and be damaged.