Display

Item

Contents

Initial User 

value

level

UF- 1

User function 

- - - -

1

definition 1

UF-2

User function

- - - -

1

definition 2

UF-3

User function

- - - -

1

definition 3

UF-4

User function

- - - -

1

definition 4

UF-5

User function

- - - -

1

definition 5

UF-6

User function

- - - -

1

definition 6

UF-7

User function

- - - -

1

definition 7

UF-8

User function

- - - -

1

definition 8

E4

Display

Item

Contents

Initial User 

value

level

Ot 1. 1

to

Control output 

0: Input of default

0

2

Ot2. 1

1 to 2, event output 1: MV1 (ON/OFF control output, time proportional 

Ev 1. 1

to

1 to 3 operation 

output,heat-side proportional output of heat/cool 

Ev3. 1

type

control)

2: MV2 (cool-side proportional output of heat/cool 

control)

3: Function 1 ((A and B) or (C and D))

4: Function 2 ((A or B) and (C or D))

5: Function 3 (A or B or C or D)

6: Function 4 (A and B and C and D)

Ot 1. 2

to

Control output 

0: Normally open (OFF, 0)

14 to 15

2

Ot2. 2

1 to 2, event output 1: Normally close (ON, 1)

or

Ev 1. 2

to

1 to 3 output 

2: Internal event 1

2 to 4

Ev3. 2

assignment A

3: Internal event 2

4: Internal event 3

5: Internal event 4

6: Internal event 5

7 to 13: Undefined

14: MV1

Ot 1. 3

to

Control output 

15: MV2

0

2

Ot2. 3

1 to 2, event output 16 to 17: Undefined

Ev 1. 3

to

1 to 3 output 

18: DI1

Ev3. 3

assignment B

19: DI2

20 to 25: Undefined

26: Internal contact 1

27: Internal contact 2

28: Internal contact 3

29 to 33: Undefined

Ot 1. 4

to

Control output 

34: Communication DI1

0

2

Ot2. 4

1 to 2, event output 35: Communication DI2

Ev 1. 4

to

1 to 3 output 

36: Communication DI3

Ev3. 4

assignment C

37: Communication DI4

38: MANUAL mode

39: READY mode

40: Invalid

41: During AT execution

42: During SP ramp

Ot 1. 5

to

Control output 

43: Undefined

0

2

Ot2. 5

1 to 2  event output 44: Alarm is enabled.

Ev 1. 5

to

1 to 3 output 

45: PV alarm is enabled.

Ev3. 5

assignment D

46: Undefined

47: mode key function selection status

48: Event output 1 status

49: Control output 1 status

Display

Item

Contents

Initial User 

value

level

dI 1. 3

to

Internal contact  

0: Normally open (OFF, 0)

2 to 4

2

dI3. 3

1 to 3

1: Normally close (ON, 1)

Input assignment A 2: DI1

3: DI2

4 to 9: Undefined

10: Internal event 1

11: Internal event 2

dI 1. 4

to

Internal contact  

12: Internal event 3

0

2

dI3. 4

1 to 3

13: Internal event 4

Input assignment B 14: Internal event 5

15 to 17: Undefined

18: Communication DI1

19: Communication DI2

20: Communication DI3

dI 1. 5

to

Internal contact 

21: Communication DI4

0

2

dI3. 5

1 to 3

22: MANUAL mode

Input assignment C 23: READY mode

24: Undefined

25: During AT execution

26: During SP ramp

27: Undefined

dI 1. 6

to

Internal contact 

28: Alarm is enabled.

0

2

dI3. 6

1 to 3

29: PV alarm is enabled.

Input assignment D 30: Undefined

31: Mode key function selection status

32: Event output 1 status

33: Control output 1 status

dI 1. 7

to

Internal contact 

Digits are called as 1st digit, 2nd digit, 3rd digit and 

0000

2

dI3. 7

1 to 3

4th digit from the right end digit.

Polarity A to D
1st digit: Polarity A 0: Direct

0

(Polarity of input 

1: Reverse

assignment A)
2nd digit: Polarity B

0

(Polarity of input 

assignment B)
3rd digit: Polarity C

0

(Polarity of input 

assignment C)
4th digit: Polarity D

0

(Polarity of input 

assignment D)

dI 1. 8

to

Internal contact 

0: Direct

0

2

dI3. 8

1 to 3 Polarity 

1: Reverse

dI 1. 9

to

Internal contact 

0: Every internal event

0

2

dI3. 9

1 to 3 

1 to 5: Internal event numbers

Internal event 

No.assignment

Display

Item

Contents

Initial User 

value

level

Ot 1. 6

to 

Control output 1 to  Digits are called as 1st digit, 2nd digit, 3rd digit and

0000

2

Ot2. 6

2, event output 1 to 4th digit from the right end digit.

Ev 1. 6

to

2   Polarity A to D

Ev3. 6

1st digit: Polarity A  0: Direct

0

2nd digit: Polarity B 1: Reverse

0

3rd digit: Polarity C

0

4th digit: Polarity D

0

Ot 1. 7

to 

Control output 1  

0: Direct

0

2

Ot2. 7

to 2, event output  1: Reverse

Ev 1. 7

to 

1 to 3 

Ev3. 7

Polarity

Ot 1. 8

to 

Control output 1 

0: Disabled

0

2

Ot2. 8

to 2, event output  1: Enabled (Latch at ON)

Ev 1. 8

to 

1 to 3  

2: Enabled (Latch at OFF, except at the time of 

Ev3. 8

Latch

initialization  after power ON)

Display

Item

Contents

Initial User 

value

level

Id0 1

ROM   ID

0: fixed

-

2

Id02

ROM version 1

XX. XX (2 digits after decimal point)

-

2

Id03

ROM version 2

XX. XX (2 digits after decimal point)

-

2

Id04

SLP support 

-

2

Information

Id05

EST support 

-

2

version

Id06

Manufacturing 

Year - 2000

-

2

date code (year)

Ex.: “3” means the year 2003.

Id07

Manufacturing 

Month + Day

100

-

2

date code (month,  Ex.: “12.01” means the 1st day of December

day)

Id08

Serial No.

-

2

Display

Item

Contents

Initial User 

value

level

dI 1. 1

to

Internal contact 1  0: No function

0

0

dI3. 1

to 3

1: LSP group selection (0/+1)

Operation type

2: LSP group selection (0/+2)

3: LSP group selection (0/+4)

4: Invalid

5: Invalid

6: Invalid

7: RUN/READY selection

8: AUTO/MANUAL selection

9: Invalid

10: AT Stop/Start

11: ST Disabled/Enabled

12: Control action direct/reverse selection (As per 

setting/opposite operation of setting)

13: SP ramp Enabled/Disabled

14: PV hold (No-hold/Hold)

15: PV maximum value hold (No-hold/Hold)

16: PV minimum value hold (No-hold/Hold)

17: Timer Stop/Start

18: Release of all DO latches (Continue/Release)

19: Invalid

20: Invalid

dI 1. 2

to

Internal contact 1  0: Disabled. (Input of default)

0

2

dI3. 2

to 3

1: Function 1 ((A and B) or (C and D))

Input bit operation 2: Function 2 ((A or B) and (C or D))

3: Function 3 (A or B or C or D)

4: Function 4 (A and B and C and D)

Event assignment bank
Bank selection: 

EvCF

DI assignment bank

Bank selection: 

dI

Lock bank
Bank selection: 

LOC

Instrument information bank
Bank selection: 

Id

Display

Item

Contents

Initial User 

value

level

LOC

Key lock

0: All settings are enabled.

0

0

1: Mode, event, operation display, SP, UF, lock, 

manual MV, and mode key can be set.

2: Operation display, SP, UF, lock, manual MV, and 

mode key can be set.

3: UF, lock, manual MV, and mode key can be set.

C. LOC

Communication 

0: RS-485 communication read/write is enabled.

0

2

lock

1: RS-485 communication read/write is disabled.

L. LOC

Loader lock

0: Loader communication read/write is enabled.

0

2

1: Loader communication read/write is disabled.

PASS

Password display

0 to 15

0

0

5: Password 1A to 2B display

PS 1A

Password 1A

0000 to FFFF (hexadecimal value)

0000

0

PS2A

Password 2A

0000 to FFFF (hexadecimal value)

0000

0

PS 1b

Password 1B

0000 to FFFF (hexadecimal value)

0000

0

PS2b

Password 2B

0000 to FFFF (hexadecimal value)

0000

0

DO assignment bank
Bank selection: 

dO

User function bank
Bank selection: 

UF

Display

Item

Contents

Initial User 

value

level

E 1. C 1

to 

Operation type of  0: No event

0

0

E5. C 1

internal event 1 to  1: PV high limit

5 configuration 1

2: PV low limit

3: PV high/low limit

4: Deviation high limit

5: Deviation low limit

6: Deviation high/low limit

7: Deviation high limit (Final SP reference)

8: Deviation low limit (Final SP reference)

9: Deviation high/low limit (Final SP reference)

10: SP high limit

11: SP low limit

12: SP high/low limit

13: MV high limit

14: MV low limit

15: MV high/low limit

16: CT1 heater burnout/over-current

17: CT1 heater short-circuit

18: CT2 heater burnout/over-current

19: CT2 heater short-circuit

20: Loop diagnosis 1

21: Loop diagnosis 2

22: Loop diagnosis 3

23: Alarm (status)

24: READY (status)

25: MANUAL (status)

26: Invalid

27: During AT execution (status)

28: During SP ramp (status)

29: Control direct action (status)

30: ST execution (status)

31: Invalid

32: Timer (status)

E 1. C2

to

Internal event 1 to  Digits are called as 1st digit, 2nd digit, 3rd digit and 

0000

0

E5. C2

5 Configuration 2

4th digit from the right end digit.

1st digit:

0: Direct

0

Direct/Reverse

1: Reverse

2nd digit: Stand-by 0: None

0

1: Standby

2: S Standby at SP change

3rd digit: EVENT 

0: Continue

0

state at READY

1: Forced OFF

4th digit: Undefined 0

0

E 1. C3

to

Internal event 1 to Digits are called as 1st digit, 2nd digit, 3rd digit and

0000

2

E5. C3

5 Configuration 3

4th digit from the right end digit.

1st digit: Alarm OR 0: No event

0

1: Alarm OR operation

2: Alarm AND operation

3: Alarm r OR operation

4: Alarm r AND operation

2nd digit: Special  0: As normal execution

0

OFF

1: Event OFF at the event setting value (main)=0

3rd digit: Delay 

0: 0.1s

0

time unit

1: 1s

2: 1min

4th digit: 

0

0

Undefined

This is the display in upper display. The setup 

exception is as follows:

----

: Yet to be registered.

P--

:

Proportional band of the PID group in use

I--

:

Integration time of the PID group in use

d--

:

Derivative time of the PID group in use

rE--

: Manual reset of the PID group in use

OL--

: MV low limit of the PID group in use

OH--

: MV high limit of the PID group in use

P--C

: Cool-side proportional band of the PID

group in use

I--C

: Cool-side integration time of the PID group

in use

d--C

: Cool-side derivative time of the PID group

in use

Ol.-C

: Cool-side MV low limit of the PID group in

use

Oh.-C

: Cool-side of MV high limit of the PID group

in use

1st edition: Mar. 2006

13th edition: Mar. 2015 (F) 

E8

Содержание C15M

Страница 1: ...lure to do so might cause electric shock fire or faulty operation Do not allow lead clippings chips or water to enter the controller case Doing so might cause fire or faulty operation Firmly tighten t...

Страница 2: ...circuit is cut off If you connect two or more current input type controllers in series change the current input to voltage input by connecting a resistor No 81401325 sold separately Prepare a heater c...

Страница 3: ...64 JPt100 0 0 to 200 0 0 to 400 67 Pt100 0 to 500 0 to 900 68 JPt100 0 to 500 0 to 900 rdy man ev1 ev2 ev3 ot1 ot2 para mode pv sp 2 3 6 5 1 4 SDC15 7 SDC15 Alarm code Error Cause Countermeasure AL01...

Страница 4: ...3 C 1 FS at 0 to 1mA Event relay outputs ev1 to 3 Contact rating 250Vac 30Vdc 2A resistive load Life Min 100 000 operations Min switching specification 5V 10mA Reference value RS 485 communication Tr...

Страница 5: ...ress Setting is disabled 0 At 1 display display 1st digit Except for 0 During execution of AT example Numeric value Value is decreased at right end digit 0 Completion of AT Ct 1 CT Current Setting is...

Страница 6: ...play Item Contents Initial User value level C 0 1 PV input range Thermocouple T 1 to 6 9 to 11 13 to 21 24 25 1 0 type RTD R 41 to 46 51 to 54 63 64 67 68 41 DC current voltage L 84 86 to 90 88 C 02 T...

Страница 7: ...ty of input assignment D dI 1 8 to Internal contact 0 Direct 0 2 dI3 8 1 to 3 Polarity 1 Reverse dI 1 9 to Internal contact 0 Every internal event 0 2 dI3 9 1 to 3 1 to 5 Internal event numbers Intern...

Страница 8: ...al No 2 Lock bank Bank selection LOC Instrument information bank Bank selection Id Display Item Contents Initial User value level LOC Key lock 0 All settings are enabled 0 0 1 Mode event operation dis...

Страница 9: ...C1 CP UM 5410EC C15M http www azbil com cn products order html 2006 2015 Azbil Corporation All Rights Reserved PV C15MT 81409651 001 1 81409657 001 1 CP UM 5410EC 1 C1...

Страница 10: ...1 2 RS 485 C15MT 59 60 2 44 8 48 48 rdy man ev1 ev2 ev3 ot1 ot2 para mode pv sp M3 SDC15 0 0 5 45 50 0 0 5 45 30 0 0 5 48xN 3 0 0 5 45 N 1 2 3 1 2 1 2 3 4 5 6 13 14 15 16 17 18 7 8 9 10 11 12 4 5 6 4...

Страница 11: ...Pt100 200 200 44 JPt100 200 200 45 Pt100 100 300 46 JPt100 100 300 51 Pt100 50 0 200 0 52 JPt100 50 0 200 0 53 Pt100 50 0 100 0 54 JPt100 50 0 100 0 63 Pt100 0 0 200 0 64 JPt100 0 0 200 0 67 Pt100 0 5...

Страница 12: ...24mAdc OFF ON 10s 1ms 10s 250ms 0 20mAdc 4 20mA 600 0 5 FS 23 3 0 1mA 1 FS ev1 250Vac 30Vdc 2A 10 5V 10mA RS 485 3 4800 9600 19200 38400bps CPL MODBUS 0 50 0 40 10 90 RH AC 85 264Vac 50 60Hz 2Hz 100...

Страница 13: ...0 1s 0 2 E1 oF E5 oF 1 5 OFF 0 2 0 1 2 PID PID P 1 0 1 999 9 5 0 0 I 1 0 9999s 0 120 0 d 1 0 9999s 0 30 0 rE 1 10 0 110 0 50 0 0 oL 1 10 0 110 0 0 0 1 oH 1 10 0 110 0 100 0 1 P 1C 0 1 999 9 5 0 0 I 1C...

Страница 14: ...1 0 MV 1 MV 2 MV 3 PV 4 PV 5 SP 6 PV SP 7 CT1 8 CT2 9 MFB C15M 10 SP MV 11 PV MV 0 0 C44 1 1999 9999 1 0 0 0 C45 1 100 0 0 C46 1 MV 0 9999 PV 200 0 C47 2 1 13 0 C48 2 0 C49 2 1999 9999 2 0 0 C50 2 10...

Страница 15: ...3 A 0 OFF 0 1 ON 1 2 DI1 3 DI2 4 9 10 1 11 2 12 3 13 4 14 5 15 17 18 DI1 19 DI2 20 DI3 21 DI4 22 MANUAL 23 READY 24 25 AT 26 SP 27 28 29 PV 30 31 mode 32 1 33 1 2 4 2 dI1 4 dI3 4 1 3 B 0 2 dI1 5 dI3...

Страница 16: ...mode 3 UF MV mode 0 0 C LoC 0 RS 485 read write 1 RS 485 read write 0 2 L LoC 0 read write 1 read write 0 2 PASS 0 15 5 1A 2B 0 0 PS1A 1A 0000 FFFF 16 0000 0 PS2A 2A 0000 FFFF 16 0000 0 PS1b 1B 0000 F...

Отзывы: