42
Chapter 6. Maintenance and Inspection
Alarm codes and details
When lockout occurs, an alarm code is displayed automatically. When an alarm
occurs, the sequence number and alarm code issued when the lockout.”
If the sequence cannot be specified, the sequence code displayed when lockout
occurred may be shown as [– –] (stopped).
Alarm
code
Sub-
code
Description
Status
Cancellation
method
E
1
None
False flame
The flame signal is detected for 15 s during prepurge
Reset
E6
Ignition failure
Ignition was not detected during the lockout time.
Reset
E7
Flame failure
The flame signal disappeared during standby for normal combustion or thereafter.
Reset
E9
02
Switch input error
The DISP switch, RESET switch or reset input stayed on for 60 seconds.
Or, one minute passed with the contact reset input ON.
Note: Monitoring is continuous while power is supplied.
Reset
E9
03
Internal relay feedback (K1)
Relay K1 failure (contact welding)
Note: If this error recurs even after a manual reset, a device failure may have
occurred.
Reset
E9
05
Terminal 7 voltage discrepancy
(PV)
At terminal 7, while pilot valve or main valve output was OFF, voltage was detected
for 30 seconds.
Note: This error can occur because of a ground fault, voltage supply to terminal
7 from an external circuit (bypass circuit, etc.), or relay K3 failure (contact
welding, etc.).
Reset
E9
06
Terminal 8 voltage discrepancy
(MV)
At terminal 8, while main valve output was OFF, voltage was detected for 30
seconds.
Note: This error can occur because of a ground fault, voltage supply to terminal
8 from an external circuit (bypass circuit, etc.), or relay K4 failure (contact
welding, etc.).
Reset
E9
07
Terminal 6 voltage discrepancy
(IG)
At terminal 6, while the ignition transformer output was OFF, voltage was detected
for 30 seconds.
Note: This error can occur because of a ground fault, voltage supply to terminal
6 from an external circuit (bypass circuit, etc.), or relay K5 failure (contact
welding, etc.).
Reset
E9
08
Alarm generation when power
is turned ON
When the cause of lockout cannot be identified
•
Power was turned off before CPU error judgment after lockout occurred
•
Latch relay was set to lockout due to vibration during transport or for other reasons
This does not indicate a problem with the device. Reset the device to restore normal
operation.
Reset
E9
50
ROM failure
ROM check code error
Reset
E9
5
1
Memory read error
Internal memory read error
Reset
E9
52
Memory write error
Internal memory write error
Reset
E9
53
Memory data error
Internal memory check code error
Reset
E9
54
CPU communication error
CPU communication error
Reset
E9
55
Diagnosis of the input circuit
Detection of part failure (voltage applied to the input terminal by wrong wiring) or
strong inductive electrical noise to the signal wire
Reset
E9
56
Input safety pulse error
Internal clock error
Reset
E9
57
CPU diagnosis (EEPROM data
error)
Error during CPU check
•
Because of EEPROM failure, EEPROM data differed
Reset
E9
58
CPU diagnosis (parameters)
Error during CPU check
Reset
E9
59
CPU diagnosis (timer)
Error during CPU check
Reset
E9
60
CPU diagnosis (process)
Error during CPU check
Reset
E9
6
1
CPU diagnosis (process
synchronization)
Error during CPU check
Reset
E9
62
Alarm relay timeout
Internal feedback signal error of alarm output relay
Reset
E9
63
CPU diagnosis
Internal memory data error
Reset
E9
64
Flame circuit diagnosis
Error in the circuit for diagnosing the flame detector circuit
Reset
E9
65
Flame circuit diagnosis
Error in the interactive diagnosis of the flame detector circuit
Reset
E9
66
K1 relay circuit error
Internal fuse blown, or internal feedback signal error
Reset
E9
68
K3 relay circuit error (PV)
Internal feedback signal error
Reset
E9
69
K4 relay circuit error (MV)
Internal feedback signal error
Reset
E9
70
K5 relay circuit error (IG)
Internal feedback signal error
Reset
E9
7
1
POC (shutoff valve proof of
closure) setting error or internal
memory read error
Internal memory read error
•
Because of EEPROM failure, EEPROM data differed
Reset
Note: If lockout occurs even if reset is repeated, the device has failed.