30
AXOR Industries
Service Manual
Magnum400
TM
ver.2 rel.05/'15
2.12 Digital inputs connection
DiGital iNPutS connection
notes
:
•
The enable signal should be +
24vdc-7ma
(PLC compatible). The enable range is between
+14v
min
and
+30v max
.
•
The
m2-4
terminal (
dgT-in1 (enaBle)
) is used only as the drive’s enable. If M2-4 is HIGH
(+24VDC) the drive is enabled (without active alarms and if start up sequence, illustrated on para
-
graph 2.21, is respected); if M2-4 is LOW (0V), the motor is without torque.
ATTENTION: THE DRIVE'S ENABLE/DISABLE, BY USING THE ENABLE INPUT, IS NOT CONSIDERED A
SECURITY FUNCTION.
•
The other inputs can be used to activate pre-programmed functions of the drive (for example: limit
switch , electromechanical brake, homing and positioning procedures, emergency stop, etc.).
For a detailed description of the pre-programmed functions see enclosure "
Speeder One
Interface",
"Additional Features Manual" and "Positioner Manual" on the CD provided with the drive.
•
Connect pin
m2-13
(
dgT-in rTn
) to the ground bar of the system.
DGT- IN RTN
I/O GND
DGT-IN5
DGT-IN1
(ENABLE)
+24VDC
refered to I/O GND
CN
MAGNUM400
TM
M2
4
8
5
6
7
9
10
11
12
13
DGT-IN2
DGT-IN3
DGT-IN4
DGT-IN6
DGT-IN7
DGT-IN8
DGT-IN9
10k
DGT-IN RTN
5V1
DGND