2.23 Motor Test
This procedure is a guide line for the first power up of the drive-motor system.
it must only be exe-
cuted by technically qualified personnel. if you need more information contact axor.
1) Follow the basic procedure previously described.
aTTenTion: do not apply load to the motor.
2) Install
Speeder One
interface from CD.
3) Power up the drive: apply the auxiliary supply and then the main supply (follow the procedure
previously described).
4) Open the
Speeder One
interface clicking on "Axormb.exe" executable file on directory: "C:\Programm\
Axor". The main window "
axor servo drive
" and the "
select driver
" windows open simultaneously.
On the
select driver
window insert the drive's address (all drives have
1 set
as default value), then
click OK.
5) If the drive is "
Not configured
", it is necessary to open a pre-set connfiguration file, following this
procedure:
- in the main window select the "
file
"menu and then "
open
";
- in the directory: ...\Axor\Data\Devices\ select a file reference to the coupling drive-motor, then
click on “
open
”;
- save load parameters by using "
save data To eeprom
" icon.
If the drive is
configured for a specified motor
, it is sufficient to check these parameters:
Main voltage (
Main Voltage
menu in the main window of the interface)
Number of motor poles (
Motor
window)
Feedback type(
Motor
window)
Encoder impulse/rev or resolver n° of poles (
Motor
window)
Irms current(
Current
window)
Ipk current (
Current
window)
Speed Limit (
Speed
window)