34
AXOR Industries
Service Manual
MiniMagnum
TM
ver.1 rev.05/'15
2.18 Feedback signals connections
SIN INPUT
COS INPUT
PTC INPUT
PTC MOTOR
4V RMS
25
16
23
14
24
15
4
17
8
13
+ECC
-ECC
+SEN
-SEN
+COS
-COS
Drive side
Motor side
RESOLVER
J1
5
9
3
7
4
8
2
6
AGND
Motor Cable
Drive
Motor
20:50cm
Max 25m
12 pole connector
(Resolver)
1
9
8
2 10 12
7
3
11
6
4
5
PE
*
1 2 3 4
5 6 7 8
9 10 11 12 13
14 15 16 17 18 19 20 21 22 23 24 25
j1 connector
sub-d 25 pole
OPTIONAL
ResolveR feedBacK connection
if the motor does not have thermal protection (pTc moToR) you should bridge pins 4
and 17 on the "j1, sub-d 25 pole" connector of the drive.
Note
: The
ground connection
of the external shield must
be made on the zinc-coated panel (using a u-clamp) near the
drive (20-50cm).
Motor side: the shield is connected to connector's metal
ring.