that may damage your meter. Note - indentifies symbols from which you can understand operation and features of your
meter. For related international symbols used by the Meter and the Manual, please read table below for reference.
Warning

Do not use the meter if it is damaged. Before using the meter, inspect the case. Look for cracks or missing plastic.
Pay particular attention to the insulation surrounding the connectors.

Make sure the battery door is closed and latched before operating the meter.

Do not use the meter if it operates abnormally. Protection may be impaired. When in doubt, have the meter serviced.

Do not operate the meter around explosive gas, vap or, or dust.

Use only type AA batteries, properly installed in the meter case to power the meter.

Use caution when working above 30V AC RMS, 42V AC PK, or 60V DC. Such voltages pose a shock hazard.

When using the probes, keep fingers behind the finger guards on the probes.

Connecting the common test lead before connecting the live test lead. When disconnecting test leads, disconnect the
live test lead first.

Read carefully and make sure well understanding of this Manual before use.

Make sure the requirements in the Manual are strictly followed and keep the Manual for reference whenever needs.

Mis-operation may cause accidents and damages to the Meter in testing.

Caution!
To avoid possible damage to the Meter or to equipment under test:

Make sure the rotary switch is in the right position, disconnect the testing leads and the circuit under test before
rotating, conversion in testing is prohibited in case of damaging the Meter.

Cut all the power off and release electricity fully from all capacitor before testing online resistance, diode and
continuity.

Check fuse in the Meter before testing current. Cut off the power before connection. Remember: when testing current,
connect the Meter with the Circuit in series. Do not connect testing leads to any circuit in parallel.

Do not use the Meter if symbol ” ” displays.

Do not store or use the Meter in high temperature, high moisture, explosive, inflammable, strong electromagnetic
environment and dew or direct sunlight place.

Do not use abrasive or solvent to clean the Meter, use a damp cloth or neutral detergent instead.

Make dry before store if the Meter is damp.

1.4. Symbols

AC Current
DC Current
AC or DC
Low Battery
Conforms to Standards of European Union
Earth ground
Double Insulated

Содержание AX-C705

Страница 1: ...oduct to see whether it is damaged in the shipment or not Check the materials to see whether they are the same as shown in the packing list Keep the packing materials for late delivery Standard and ch...

Страница 2: ...l understanding of this Manual before use Make sure the requirements in the Manual are strictly followed and keep the Manual for reference whenever needs Mis operation may cause accidents and damages...

Страница 3: ...the level of protection for the pulse compression typical installation location includes Three phase utility power supply equipment for any outdoor power lines or equipment Any outdoor transmission li...

Страница 4: ...n stable 2 3 DC voltage measurement Turn the rotary switch to Insert black probe into COM terminal and insert red probe into _V terminal Connect the probes to the circuit under test and then read the...

Страница 5: ...e electricity fully from all capacitor before testing continuity Turn the rotary switch to D press green button and select test Insert black probe into COM terminal and insert red probe into _V termin...

Страница 6: ...d 250 HART Insert black probe into mA terminal and insert red probe into LOOP terminal Connect the probes to the circuit under test and then read the measured value when stable Press mA button to disp...

Страница 7: ...A output Otherwise low impedance from other position of rotary switch will appear and cause current higher than 35mA to go through the loop circuit Turn the rotary switch to the screen displays OUTPUT...

Страница 8: ...and latch the battery door before using the meter Note The new and old Batteries can not be mixed Max Voltage applied to output terminals about 32V Max current applied to output terminals about 25mA M...

Страница 9: ...to IEC61326 1 Group 1 Class B Surge protection 8kV according to IEC61010 1 2001 Identification Mark CE Quality Standard Develops designs and manufactures in conformity with ISO 9001 4 2 General featu...

Страница 10: ...ark DC voltage 50V 10mV 0 5 4 Measuring impedance 10 M standard value Common mode restrain 50Hz or 60Hz 100Db String mode restrain 50Hz or 60Hz 45dB Overload protection 600V peak peak value AC voltage...

Страница 11: ...transmitter 20mA 0 000 22 000mA 0 001mA 0 2 4 external power supply 5 28V Max load 1k at 20mA LOOP Loop circuit power 24V 10 Max output current 25mA Max Voltage applied to output terminals about 32V...

Отзывы: