Operation instructions | SKT 40-00 | SKT 80-00 | 8PSK/QPSK | COFDM Quattro/Octo Module
10
2016-01-11 | © AXING AG Switzerland | Subject to change in design and type; errors and misprints reserved
2.1.1.
Power supply in the headend base unit
The power supply units supply the modules with 16 V DC voltage. The current consumption of all connected
modules must not exceed the maximal delivery of the power supply unit used.
The remote power rails at the SAT IF inputs must be added to the current consumption of the modules. The
current consumption at the SAT IF inputs is limited to 250 mA per input. Please take account of the current
consumption of the devices when choosing the LNBs or the multiswitches.
SKS 4-00 /
SKZ 5-01 (10 A)
SKS 40-00* /
SKZ 5-01 (10 A)
SKS 40-00* /
SKZ 5-04 (2×10
A)
SKS 8-00 /
SKZ 6-00 (18 A)
SKT 40-0x
1.5 A + LNB current
consumption
4
4
4
8
SKT 80-0x
3A + LNB current
consumption
3
3
4
5
*Please note: The SKS 40-00 is supplied without power supply unit and remote control.
2.2.
External operation of the SKT 40-00 / 80-00 module
Î
Please note that the installation must be carried out on an even and vertical surface.
Î
Any unevenness must be compensated.
Î
Fix the module with 2 screws appropriated for the installation surface.
Î
Install the module in compliance with the safety regulations defined by the EN 60728-11 standard.
Î
Connect the module with an equipotential bonding cable (copper, minimum 4 mm²).
Î
For an operation without a basic unit, the outputs of several modules must be combined with a
distributor.