The input port for a single stream or for all streams can also be switched manually. If the user switches the input port manually,
the automatic switch-back for this stream is deactivated until the restart.
3.4.
Initialization - phase 2
Click on PHASE 2, to select programs.
The
TS IDs
(transport stream IDs), the
Network ID
and the
Network Name
can be changed. If you use several MIE in a network,
then the network IDs must be the same and the network name should also be the same. Transport stream IDs, on the other hand,
may only be assigned once in the network.
Different LCN standards can be selected with the drop down menue
Region
.
3.4.1.
Assigning programmes
Every tuner is assigned to a modulator. The programmes of the tuner can only be assigned to the associated modulator.
For example, click on M1.
The program is assigned to modulator 1. The button of the modulator is highlighted in color (a new click on a modulator allow
the assignment to be canceled. The modulator fades then again).
Click on SAVE CHANGES.
The assignment is saved to the device.
Modulator fill level
The modulator fill level is displayed in a status overlay. This status overlay can be moved on the page.
The
X
button hides the status overlay. The
Save
button saves configuration changes and then displays the new modulator fill
level.
Chosen
programs for
modulators 1
to 8