AVTECH Inc.
7
TemPageR 3E
Installation
2. Click ‘Ok’ on the first dialog that displays and enter the TemPageR 3E MAC address when
prompted. The MAC address is listed on the label located on the bottom of the TemPageR 3E.
3. Enter a valid static IP address for the current location of the TemPageR 3E unit when prompted.
NOTE: If the TemPageR 3E unit is later relocated outside of the current subnet, you will need to reset the IP address in order to
see and work with the TemPageR 3E unit.
If the TemPageR 3E unit is still not discovered or the IP address is not updated, continue with steps 4-6.
4. Locate a cross-over Ethernet cable or spare hub and connect it to the computer being used.
Connect the TemPageR 3E to the other end of the cross-over Ethernet cable or directly to the hub.
5. Assign static IP settings to the computer being used. If the ‘Search’ button is pressed after doing so,
the TemPageR 3E unit should be discoverable. If it is not, be sure that there are no applications on
the computer being used that are blocking traffic sent to or from the AVTECH Device Discovery
Utility (i.e. software firewalls, anti-virus applications, etc.)
6. Repeat steps 1-3 above although enter a static IP address in step 3 that has the same first three
octets as the static IP address assigned to the computer (i.e. IP address of computer: 192.168.2.3, IP
address of TemPageR 3E: 192.168.2.4).
If the IP address of the TemPageR 3E unit is still not updated, continue with steps 7-9.
7. Assign static IP settings to the computer being used that match the IP address of the TemPageR 3E
unit (i.e. IP address of TemPageR 3E: 169.254.10.122, IP address of computer: 169.254.10.123).
8. Click the ‘Search’ button in the AVTECH Device Discovery Utility and select the TemPageR 3E unit
when discovered.
9. Click the ‘Set IP’ button and enter a valid IP address for the location on the network where
the TemPageR 3E unit will be located. If the IP address does not update, access the ‘Settings’
screen of the TemPageR 3E unit and enter the IP address settings on the ‘Network’ tab. After
doing so, click the ‘Save Settings’ button, wait 10 seconds and re-attach the TemPageR 3E unit to
the network.
Device Not Found Or Invalid IP Address
If the TemPageR 3E is not discovered by the AVTECH Device Discovery Utility, the network may be
blocking UDP broadcast packets on port 30718. Even if the TemPageR 3E obtains a valid IP address,
this can prevent the TemPageR 3E unit from being discovered. To resolve this issue, check the DHCP
server for the MAC address listed on the label located on the bottom of the TemPageR 3E unit. If this
is not possible or if there is not an entry in the DHCP server, follow the instructions listed under the
‘Static-Only Networks’ subsection above.