TYPICAL RESULTS
OUT1
When OUT1 is connected to a 50 Ohm load (using the arrangement shown in the
"BASIC TEST ARRANGEMENT, WITHOUT OUTPUT MODULES" section), waveforms
similar to the one shown below will be obtained:
Pulser settings: 100 Hz, +250V, 2.5 us PW.
Rise/Fall reference levels: 10%, 90%.
When OUT1 is connected to the AVX-TEK3-TM1 (using the arrangement shown in the
"BASIC TEST ARRANGEMENT, WITH OUTPUT MODULES" section) and a Tektronix
A6303 probe system, waveforms similar to the one shown below will be obtained:
Pulser settings: 100 Hz, +250V, 2.5 us PW.
Rise/Fall reference levels: 10%, 90%.
Probe/scope settings: 10 mV = 1 A.
28
Содержание AVR-3-PW-TEK3-B
Страница 31: ...Larger values of attenuation 6 dB will reduce the reflections and the pulse amplitude further 31 ...
Страница 42: ...PCB 158R4 LOW VOLTAGE POWER SUPPLY ...
Страница 43: ...PCB 235B HIGH VOLTAGE DC POWER SUPPLY ...
Страница 44: ...PCB 284B HIGH VOLTAGE DC POWER SUPPLY WITH DISCHARGE ...
Страница 46: ...PCB 241B DUAL CHANNEL PULSE WIDTH BOARD ...
Страница 51: ...PERFORMANCE CHECK SHEET 51 ...