![Avonic CM60-IP Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/avonic/cm60-ip/cm60-ip_user-manual_3033795043.webp)
www.avonic.eu
43
Call Preset
0xA0 Address 0x00
0x07
0x00
Preset ID 0xAF XOR
Auto Focus
0xA0 Address 0x00
0x2B
0x00
0x01
0xAF XOR
Manual Focus
0xA0 Address 0x00
0x2B
0x00
0x02
0xAF XOR
Query
Pan
Position
0xA0 Address 0x00
0x51
0x00
0x00
0xAF XOR
Query
Pan
Position
Response
0xA0 Address 0x00
0x59
Value
High Byte
Value
Low Byte
0xAF XOR
Query Tilt Position
0xA0 Address 0x00
0x53
0x00
0x00
0xAF XOR
Query Tilt Position
Response
0xA0 Address 0x00
0x5B
Value
High Byte
Value
Low Byte
0xAF XOR
Query
Zoom
Position
0xA0 Address 0x00
0x55
0x00
0x00
0xAF XOR
Query
Zoom
Position
Response
0xA0 Address 0x00
0x5D Value
High Byte
Value
Low Byte
0xAF XOR
VISCA over IP commands
The Avonic CM60-IP and CM60-IPU and CM60-IP-BOX cameras are implemented with a TCP
server. The TCP port number is 5678 by default and can be altered in the WebGUI. Once the
connection between client and server is set up, the client will be able to send PTZ commands
to the server. The server then parses and executes the PTZ command.
The Avonic IP Camera has also implemented a UDP server. The UDP port number is fixed on
1259. Once the connection between client and server is set up, the client will be able to send
PTZ commands to the server. The server then parses and executes the PTZ command.
The VISCA over IP command list is based on the VISCA protocol. Not all VISCA commands are
implemented in the VISCA over IP command list.
The PTZ Command format is according to the definition of the VISCA protocol. The VISCA
address of the camera is set to 1 by default and can be changed in the WebGUI. As all cameras
are uniquely identified by their IP address, all VISCA addresses of the cameras that are
controlled over IP do not necessarily be unique.
Default settings:
TCP port
5678
UDP port
1259
VISCA address 1
The commands are as follow: