TCP/UDP Control
The Avonic IP camera is implemented with a TCP server inside. The default TCP port number is
5678. This number can be changed in the WebGUI in the Network Menu. Once the connection
between client and server is set up, the client will be able to send VISCA PTZ commands to the
server. The server then parses and executes the VISCA PTZ command.
The Avonic IP Camera has also implemented an UDP server inside. The UDP port number is 1259.
This number cannot be changed. Once the connection between client and server is set up, the
client will be able to send VISCA PTZ commands to the server. The server then parses and
executes the VISCA PTZ command.
The PTZ Command Format is according to the definition of the VISCA protocol. The camera
address is default set to 1. This number can be changed in the WebGUI in the Network Menu.
The commands are listed in Appendix A.
WebGUI Homepage
Menu
All pages include 2 menu bars:
Real time monitoring: displaying video image Parameter setup: with function buttons
Video viewing window
Video viewing window must be same as video resolution, the bigger the resolution is, the
bigger the playing area is. Double click viewing window, will show full-screen, double click
again, will return to initialized size.
1) Video playback pause button: control
real-time video pause, stop the last picture, click recoverable video again.
2) Audio control buttons: can set silent mode.
3) Full screen switch button.