27
D400
anD
D400-D
ante
a-n
et
D
istributors
u
ser
G
uiDe
Device Config Tab
The settings for Sample Rate and Device Latency are found within the Device Config tab. Note that each
device in a Dante network has a separate setting for Sample Rate. While it is possible to have devices with
different sample rates in the same network, you cannot patch Dante channels between devices with
mismatched sample rates.
Choose a sample rate from the drop-down menu for each network device.
To change the sample rate for the D400-Dante, select a new rate from the drop-down menu. Use the radio
buttons in the Device Latency section to choose a latency value that best matches the network you have
set up. The D400-Dante is compatible with sample rates of 44.1 and 48kHz. The D400-Dante does not
contain sample rate converters.