AVG-UHMS44
Command
Function
Feedback Example
/+[Y]/[X]:******.
Set communication between PC and
HDBaseT receiver.
Y is for RS232 port (connect with
RS232 port of HDBaseT receiver)
Y= 1~5 or A~H, The value of Y is
defined into the following meanings
(in a given baud rate depended by
the value of X):
a.
Y = 1~4, send this command to the
corresponding HDBaseT receiver to
control far-end device.
b.
Y = 5, send this command to all
HDBaseT receivers to control all far-
end devices.
c.
Y = A, B, C, or D
d.
Y = E, F, G, or H
For items c or d, send this command, it
will be saved to the matrix switcher but
taken without action to corresponding
HDBaseT receiver. And its command
function will be effective almost at the
same time when you send the
command PWON (for item c) or PWOFF
(for item d).
Note:
A & E are for port 1. B & F are for port
2.
C & G are for port 3. D & H are for port
4.
X is for baud rate, its value ranges
from 1 to 7 (1--2400, 2--4800, 3--
9600, 4--19200, 5--38400, 6—57600,
7--115200)
***** is for data (max 48 Byte)
/+[Y]/[X]:******.
EDIDH[x]B[y].
Input port [y] learns the EDID from
output port [x].
If the EDID data is available and the
audio part supports not only PCM
mode, then force-set it to support PCM
mode only. If the EDID data is not
available, then set it as initialized EDID
data.
EDIDH[x]B[y].
EDIDPCM[x].
Set the audio part of input port [x] to
PCM format in EDID database.
EDIDPCM[x].