Command
Function
Feedback Example
EDIDG[x].
Get EDID data from output [x] and
display the output port number.
Hexadecimal EDID
data and carriage
return character
EDIDMInit.
Restore the factory default EDID data of
every input.
EDIDMInit.
EDIDM[X]B[Y].
Manually EDID switching. Enable
input[Y] to learn the EDID data of
output[X]. If the EDID data is not
available, then set it as initialized EDID
data.
EDIDM[X]B[Y].
EDIDUpgrade[x].
Upgrade EDID data via the RS232 port.
[x] is the input port, when the value of X
is 9, it means to upgrade all input ports.
When the switcher receives the
command, it will show a message to
prompt you to send EDID file (.bin file).
Operations will be canceled after 10
seconds. Please cut off all connections
of HDBaseT ports.
Please send the
EDID file
EDID/[x]/[y].
Set the EDID data of input port [x] to
built-in EDID No.[y].
[y]=1~5, correspond to the 5 embedded
EDID data separately
EDID/[x]/[y].
UpgradeIntEDID[x].
Upgrade one of the 5 embedded EDID
data, x is the serial number for EDID
data
1. 1080P 3D 2CH
2. 1080P 3D Multichannel
3. 1080P 2D 2CH
4. 1080P 2D Multichannel
5. 3840x2160 2D (30Hz)
When the switcher gets the command, it
will show a message to send EDID file
(.bin file). Operations will be invalid after
10 seconds.
Please send the
EDID file
GetIntEDID[x].
Return the embedded EDID data
ranked x, [x]=1~5
GetInPortEDID[X].
Return the EDID data of input [x],
[x]=1~4
%0801.
Auto HDCP management, activate
carrier native mode
%0801.
%0900.
Switch to carrier native mode.
Carrier native
%0901.
Switch to force carrier mode.
Force carrier
%0911.
Reset to factory default.
Factory Default
%9951.
Check the command sent by port 1
when PWON.
Port 1:data when
PWON