ZK830 Counting Scale User Instructions
53
8.3 Checkweighing application supervisor menu
ovErdiv
This stands for Over Divisions. Enter the number of divisions above your
high tolerance which will cause the first over segment to appear.
Example to illustrate how Lo Tol, Hi Tol, Undrdiv and Overdiv relate:
Target is 100 lb at a division size of 0.1 lb
Low tolerance 10 lb
High tolerance is 20lb
Under division is 1
Over division is 2
So the acceptable range is 90 – 120 lb
At 89.9, one under segment illuminates
At 89.8, two under segments illuminate
Below 89.7, three under segments would be shown
At 120.2, one over segment illuminates
At 120.4, two over segments illuminate
LAtcHou
This stands for Latch Output. If
On
, once a weight is stable a tripped output
will not change until the scale returns to gross zero.
oFF
disables this
function.
oFF
is the default.
This completes the Supervisor menu for the Checkweighing application. Repeatedly
press
TARE
until the indicator returns to normal weighing mode.
With
LAtcHou oFF
, the Under, Accept or Over outputs will be activated using live
weight.
With
LAtcHou on
, the weight has to stabilize before the annunciator and output for
the appropriate condition (Under, Accept or Over) are activated.