ZK830 Counting Scale User Instructions
Supervisor menu
PiE rPt
Stands for Piece Count Repeat. This causes the scale to remember the
last display weight and count. If the next weighment is the same weight or
within the number of divisions selected, the last displayed count will be
repeated. Choices:
oFF
,
1
,
2
,
5
or
10
.
PiE Stb
Stands for Piece Weight Stabilization. This causes the scale to compare a
newly calculated piece weight with the existing piece weight. If the new
piece weight is within the selected percentage of the existing piece weight,
the scale will continue to use the existing piece weight. Choices:
oFF
,
1
,
2
,
4
or
10
.
Auto bS
Stands for Automatic Base Switching: (You must have selected and
configured a remote base for this function to work.) Choose to enable or
disable auto base switching mode. Auto base switching lets you perform
sampling on one of the bases. When
ScALE 1
is selected, sampling is
performed on the local BSQ base. If
ScALE 2
is selected, sampling is
performed on the remote base. Choices:
oFF
,
ScALE 1
,
ScALE 2
.
cHK MEn
This stands for Check Menu. Use this to enable or disable check counting
(like checkweighing except counts are used instead of weight). If you
enable this function these menu items appear:
Lo LiMi
This stands for Low Limit. Enter the lowest acceptable count.
Hi LiMi
This stands for High Limit. Enter the highest acceptable count.
ovEr
This stands for Over count. Enter the number of counts which
will be equal to each over segment of the bargraph.
undEr
This stands for Under count. Enter the number of counts which
will be equal to each under segment of the bargraph.
LAtchou
This stands for Latch Output. If
On
, once a count is stable a
tripped output will not change until the scale returns to gross
zero.
oFF
disables this function.
8.2.2 PLU menu item
Use this to create, edit or clear up to 40 part lookups.
EditPLu
Enter a PLU number from 1-40.
nuMbEr
Enter a 3 to 7 digit identifier for this item or product.
unitS
Choose the unit of measure for this PLU.
tArESc1
Enter a tare weight for this PLU on scale 1. If a second scale
is enabled,
tArESc2
will appear and you can enter a tare for
this scale.
Pc Wt
Enter a piece weight value for this PLU.
SAMPLE
Use to sample parts for this PLU. This will update the
Pc Wt
value mentioned above.
Lo LiMi
Enter a low limit count. Only active if
chEcK
is enabled under
cHK MEn
.
hi LiMi
Enter a high limit count. Only active if
chEcK
is enabled under
cHK MEn
.