9
Setup
↓
Scale
→
Options
→
Security
→
Serial A / Serial B
These two serial ports allow interface with peripheral devices when the SC-150 in employed. Serial commu-
nication includes RS-232, RS-422/485 and Current Loop. These ports may be used separately or they may
be used in conjunction with each other. When the SC-150 is disabled only Serial A appears in the Configura-
tion Menu.
Setup
↓
Scale
→
Options
→
Security
→
Serial A/B
↓
↓
Button
Choosing
OFF disables the front panel PRINT button. Choosing ON enables the front panel PRINT button.
Setup
↓
Scale
→
Options
→
Security
→
Serial A/B
↓
↓
Button
→
Enquire
This option is not seen on the battery-powered version of the WI-150. On the AC//DC powered version this
sub-menu allows you to choose a printer or other device which will send an enquire code to the indicator.
You may select the ASCII code number you wish to act as the enquire code number. ASCII decimal 005 is
the default value. If a device sends the enquire character to the indicator, the indicator will transmit weight
data. If a computer sends the enquire character, the Button, Auto and Broad. selections are overridden and
will not function.
Under the Enquire, Device option, if "Printer" is selected, the display will freeze while printing, and if printing
is timed-out, a recovery menu is presented. If "Other" is selected, data are transmitted without affecting the
front panel operation.
Setup
↓
Scale
→
Options
→
Security
→
Serial A/B
↓
↓
Button
→
Enquire
→
Auto
With auto print enabled, the indicator automatically transmits data when the scale weight stabilizes at greater
than 1% of capacity. To print again, scale weight must fall below 1% of capacity and stabilize above 1% of
capacity again.
OFF disables the auto print feature. ON enables the auto print.
Setup
↓
Scale
→
Options
→
Security
→
Serial A/B
↓
↓
Button
→
Enquire
→
Auto
→
Broad.
Broad. stands for broadcast. If you enable (
ON) broadcast, the weight data to be transmitted are updated at
the display rate. Choosing
OFF disables the broadcast. If broadcast is enabled, the Button, Enquire, and
Auto selections are overridden and will not function.
Setup
↓
Scale
→
Options
→
Security
→
Serial A/B
↓
↓
Button
→
Enquire
→
Auto
→
Broad
Input
Used only with the SC-150 for remote print input.
Setup
↓
Scale
→
Options
→
Security
→
Serial A/B
↓
→
Busy
→
Enabled, Disabled
This parameter refers to the ready/busy handshake between the indicator and any peripheral devices. This
function requires two additional wires in the cable for the Clear To Send and Date Terminal Ready signals to
be used.
Setup
↓
Scale
→
Options
→
Security
→
Serial A/B
↓
→
Busy
→
Baud
↓
1200
,
2400
,
4800
,
9600
,
300
,
600
This option lets you choose the baud rate for your printer or device.
Содержание WI-150
Страница 1: ...WI 150 Ultra Low Power Weight Indicator Service Manual ...
Страница 9: ...6 Figure 2 Configuration Menu ...
Страница 10: ...7 Key Available only when SC 150 is enabled Default values ...
Страница 27: ...24 ...
Страница 29: ...WI 150 INDICATOR AC DC BARRIER POWERED CABLE TO PC BOARD CONNECTION and CABLE PIN OUTS 26 ...
Страница 30: ...WI 150 AC DC INDICATOR BATTERY POWERED CABLE TO PC BOARD CONNECTION 27 ...
Страница 31: ...WI 150 INDICATOR SYSTEM BLOCK DIAGRAM 28 ...
Страница 38: ...SC 150 REMOTE CONTROL OPTION BOARD MAIN BOARD 35 ...
Страница 41: ...SC 150 REMOTE CONTROL SYSTEM BLOCK DIAGRAM 38 ...
Страница 45: ...WI 150 INDICATOR KEYPAD AND SCHEMATIC 42 ...