8
Setup
↓
Scale
→
Options
↓
Control
→
Tare
→
ID
Choosing
ON enables the ID number. OFF disables the ID number. If ID is disabled, ID will not appear in the
SECURITY section of this menu.
Setup
↓
Scale
→
Options
↓
Control
→
Tare
→
ID
→
Cutoffs
↓
Total , Ingred., Latched
Total—
This option lets you choose the number of cutoffs you want by keying in a number. If you choose 0
(zero) cutoffs,
CUTOFFS will not appear in the SECURITY section of this menu or in the Opera-
tions Menu. Also, in order for
CONTROL to appear in the Operations Menu, a non-zero number
must be entered.
Ingred.— This option lets you choose the number of cutoffs you wish to be “ingredient cutoffs” by keying in a
number. If you pick 0,
INGRED. will not appear in the menu and the cutoffs you have will be
“setpoint cutoffs.” Cutoffs occur according to weight. The lightest cutoffs occur first, followed by
the heavier ones. See
Viewing and Setting Cutoffs in the User's Manual.
Latched— Selecting "yes" means that once a cutoff output is turned off, it is to stay off until control is halted
and then started again. Further, once all cutoffs are off, the control is automatically halted. Select-
ing "no" disables this behavior.
LATCHED is offered only if CONTROL is enabled under OPTIONS
and the total number of cutoffs is not zero. Default = yes.
Setup
↓
Scale
→
Options
↓
Control
→
Tare
→
ID
→
Cutoffs
→
Hour
With this option you can choose to have the clock disabled (
OFF) or the mode of clock you want. You can
choose the 12 hour clock display or the 24 hour clock display. If the clock is disabled,
HOUR will not appear
in the S
ECURITY section of this menu and DAY will not appear in the OPTIONS or SECURITY section of this
menu.
Setup
↓
Scale
→
Options
↓
Control
→
Tare
→
ID
→
Cutoffs
→
Hour
→
Day
This option lets you choose to disable the calendar (
OFF) or choose the mode of calendar display you want.
You can choose to display the days (dd), months (mm), and year (yy) as mm dd yy, or dd mm yy, or yy
mm dd. If DAY is disabled,
DAY will not appear in the SECURITY section of this menu.
Setup
↓
Scale
→
Options
→
Security
↓
Code No.
This option lets you enter a personalized security code number. Digits are not shown on the display as you
key them in so the display prompts you to enter the code number twice.
Setup
↓
Scale
→
Options
→
Security
↓
Code No.
→
Control
Enabling this function requires that the security code be keyed in before accessing the
CONTROL sub-menu
of the Operations Menu. Default = OFF.
Setup
↓
Scale
→
Options
→
Security
↓
Code No.
→
Control
→
Tare
→
→
→
→
→
ID.
→
→
→
→
→
Cutoffs
→
→
→
→
→
Hour
→
→
→
→
→
Day
Under each item you have the option of choosing
OFF to leave the option unlocked or choosing ON to lock
the option behind the security code. If
ON is chosen, the security code is needed to change that particular
parameter in the operations menu.
Содержание WI-150
Страница 1: ...WI 150 Ultra Low Power Weight Indicator Service Manual ...
Страница 9: ...6 Figure 2 Configuration Menu ...
Страница 10: ...7 Key Available only when SC 150 is enabled Default values ...
Страница 27: ...24 ...
Страница 29: ...WI 150 INDICATOR AC DC BARRIER POWERED CABLE TO PC BOARD CONNECTION and CABLE PIN OUTS 26 ...
Страница 30: ...WI 150 AC DC INDICATOR BATTERY POWERED CABLE TO PC BOARD CONNECTION 27 ...
Страница 31: ...WI 150 INDICATOR SYSTEM BLOCK DIAGRAM 28 ...
Страница 38: ...SC 150 REMOTE CONTROL OPTION BOARD MAIN BOARD 35 ...
Страница 41: ...SC 150 REMOTE CONTROL SYSTEM BLOCK DIAGRAM 38 ...
Страница 45: ...WI 150 INDICATOR KEYPAD AND SCHEMATIC 42 ...