31
WI-125 SST Indicator Service Manual
3. To move down a level in the hierarchy, press
SELECT
. Anytime you
wish to get to the next higher level in the hierarchy, press and hold
SELECT
for approximately 1.5 seconds or press
SELECT
whenever
End
is displayed.
4. Press
MENU
to toggle between choices.
5. Press
G/N
to return to gross weighing operation at any time.
Below are the specific directions and explanations for the items you see in
the test menu.
VERSION —
Under
VErSIOn
are the Weigh-Tronix part number and
revision number for the software found in your machine.
Weigh-Tronix part numbers are divided into two parts: the
prefix and the dash number. With
VErSIOn
displayed, press
SELECT
to view the prefix, then push
MENU
to view the
dash number. Press SELECT to return to
VErSIOn
.
DISPLAY —
With
diSPLAY
displayed, press
SELECT
and the bottom
row of annunciators turns on. Press
SELECT
again and a
dynamic test is run. Press
MENU
to stop the dynamic test
or consecutively press
MENU
to step through the display
test routine. Press
SELECT
when the dynamic test is active
to return the unit to
diSPLAY
.
BUTTONS — With
buttonS
displayed, press
SELECT
and an underscore
will appear on the screen. Press any key except
MENU
to
check for proper key functioning. After testing the buttons,
press
MENU
to return to the display.
OUTPUTS — These tests allow you to turn the cutoffs on and off auto-
matically in sequence, under
SEQUENCE
, or individually,
under
CUTOFF 0-7
. When you exit the outputs test, the
cutoffs revert to their proper condition according to the
weight on the scale.
A to D —
Displays the analog to digital counts. The span is normally
20000 counts per millivolt per volt. With a calibrator at zero
millivolts per volt, the displayed value should be between
-200 and +200. Press
SELECT
to return to A to D.
SERIAL —
Tells you if the serial output is ready or busy. A jumper
connecting pins DTR to CTS of the serial port will cause
REAdY
to be displayed. Pressing the
MENU
key puts
no
LOOP
on the display. With pins XMITT to RECV connected,
LOOP
is displayed. With them disconnected,
no LOOP
is
displayed. Press
SELECT
to return to
SErIAL
.
Содержание WI-125 SST
Страница 1: ...WI 125 SST Indicator Service Manual LED version LCD version...
Страница 2: ...2 WI 125 SST Indicator Service Manual...
Страница 8: ...8 WI 125 SST Indicator Service Manual Figure 2 Configuration Menu...
Страница 9: ...9 WI 125 SST Indicator Service Manual...
Страница 36: ...36 WI 125 SST Indicator Service Manual...
Страница 39: ...39 WI 125SST INDICATOR LCD VERSION 115 230VAC W O WEIGHT SENSOR CONNECTOR PC BOARD CABLE IDENTIFICATION...
Страница 41: ...41 WI 125SST INDICATOR LCD VERSION 115 230VAC W WEIGHT SENSOR CONNECTOR PC BOARD CABLE IDENTIFICATION...
Страница 43: ...43 WI 125SST INDICATOR LCD VERSION 115 230VAC W WEIGHT SENSOR CONNECTOR PC BOARD CABLE CONNECTIONS...
Страница 48: ...48 WI 125SST INDICATOR LED VERSION 115 230VAC SYSTEM BLOCK DIAGRAM...
Страница 50: ...50 WI 125SST INDICATOR LED VERSION 115 230VAC KEYPAD OPTIONAL P C BOARDS...