75
5
A
FTER
OPERATION
5.1 C
ARE
AND
CLEANING
ALS
380
Capacitive sensor at the dispenser head
Only if the labeller is equipped with a capacitive
sensor [76A] instead of the proper photoelectric sen-
sor:
➔
Remove the knurled thumb screw [76B].
➔
Remove 2 screws on the underside [77A].
➔
Remove the upper part of the housing [78A].
➔
Clean the sensor surfaces [78 arrows] with soft,
lint-free rags.
➔
Reassemble the sensor.
➔
Test the sensor adjustment.
[76]
A
Capacitive sensor
B
Knurled thumb screw
[77]
A
Fastening screws for the housing on the underside
[78]
A
Upper part of the housing with sensor surfaces (arrows)
A
B
A
A