32
4
O
PERATION
4.1 A
CTIVATION
AND
SHUT
-
DOWN
ALS
380
4.1.1
Starting the machine
Before each use, the control system must be adapted
to the inserted label material. During this, the label dis-
tance is detected and the photoelectric sensor at the
dispenser head is adapted to the transparency of the
labels and of the backing material. This process is
called
material initialisation
.
Automatic material initialisation
Initialising material at switch-on:
➔
Press and hold the FEED key [24] and switch on the
machine at the main switch [25A].
– The message AUTO appears on the operator panel.
– The machine slowly starts up and dispenses a label.
– The label distance is automatically measured.
– The photoelectric sensor is automatically adapted.
➔
Release the FEED key once a label gap has passed
the photoelectric sensor at the dispenser head.
If the initialisation was successful:
– "ON" appears on the operator panel.
– When the FEED key is pressed, a label is dis-
pensed.
If the initialisation was unsuccessful:
– The message FAIL appears on the operator panel.
➔
Switch off and automatically re-initialise the ma-
chine.
or:
➔
Manually initialise the material employing
qualified calibration technicians.