9
Technical Data
General data
Permissible medium
Compressed air in accordance
with ISO 8573-1:2010
Max. particle size
5 μm
Oil content of
compressed air
0-5 mg/m
3
The pressure dew point must be at least 15°C below the
ambient and medium temperatures and must not
exceed 3°C. The properties of the compressed air must
remain constant over the entire service life.
Min./max. operating
pressure
4–8 bar
Mounting orientation
Any
Holding force, weight, tightening torque
Cylinder
Ø
[mm]
Static
holding
force [N]
Weight
[kg]
Tightening torque
for lock nut
[Nm]
20
300
0.13
20.0 ± 1.5
25
400
0.13
20.0 ± 1.5
Holding force, weight, tightening torque
Cylinder
Ø
[mm]
Static
holding
force [N]
Weight
[kg]
Tightening torque
for mounting
screws [Nm]
32
650
0.2
9.5 ± 0.7
40
1100
0.27
9.5 ± 0.7
50
1600
0.57
19 ± 1.5
63
2500
0.8
19 ± 1.5
80
4000
1.85
40 ± 3
100
6300
2.9
40 ± 3
O
For further technical data, please see the AVENTICS
GmbH online catalog at www.aventics.com/
pneumatics-catalog.
Permissible piston rod extension
Cylinder
Ø
[mm]
Length of piston rod
extension
[mm]
Suitable piston rod
diameter
[mm]
20
54
8
25
51
10
32
42
12
40
47
16
50
57
20
63
57
20
80
77
25
100
77
25
AVENTICS
| HU1 |
R412022330–BAL–001–AB
| English