Rev:
1.00
Date:
11.22.2013
Page:
31 of 40
AIMMS-20
OPERATING MANUAL
Document-P/N:
AIMMS20-OM
© Aventech Research Inc. 2013. All Rights Reserved.
5 TECHNICAL SPECIFICATIONS
5.1 AIR DATA PROBE (ADP)
Internal Sampling Rate
200Hz
Low-pass filter frequency range
1 – 20 Hz (3 dB corner frequency)
Data Output Rate:
1 - 20 Hz
Measurement
Range
Accuracy
Static Pressure
0-110000 Pa
100Pa + 0.05%
Pitot-Static Differential
0-14000 Pa
20 Pa + 0.05%
AOA / AOS Differential
+/- 7000 Pa
20 Pa + 0.05%
Accele/-
5g
0.005g
5.2 INERTIAL MEASUREMENT UNIT (IMU)
Internal Sampling Rate:
200 Hz
Digital Low Pass Frequency:
20 Hz (3 dB corner frequency)
Data Output Rate:
40 Hz
Measurement
Range
Accuracy
3-axis accelerations
+/- 5g
0.005g
3-axis angular rates
+/- 60 deg/s
0.03 deg/s
5.3 CENTRAL PROCESSING MODULE (CPM)
Processor:
Motorola
DSP56F807
Internal FLASH Memory:
16 Mbit