number of records currently transferred to the data log file as shown below. The file
will be located in the same directory as the
aimcfg
program installation.
Once the download has completed, a dialog box will pop up indicating “Download
Complete”. Press “OK” to return to the main form.
Note
: The AIMMS CPM internal data log is reset when two conditions are met:
1) A GPS signal is available.
2) And the system has been powered up for more than one minute.
This allows the log to automatically clear itself and prepare to record a new
flight without any user actions beyond turning on the system. If the user is
unsuccessful on the first or subsequent download attempts, the system can
be powered down and another download attempt made provided the unit is
powered for no more than one minute (60 s.).