4.4.4 Raw Data Capture
Low-level system diagnostics and advanced flight-calibration data analysis are
aided by the collection of “raw” data. Selecting this menu item starts the collection of
all sensor information that is passed between the four modules of the AIMMS-20
system via the COM2 serial port of the CPM connected to your computer. A dialog
box will be displayed showing the filename being used to record the data, and the
number of bytes currently transferred. Information should accumulate at a rate of a
little more than 20 MB / hour. Simply click the “Quit” button to close the file and
terminate the raw-data collection process.
4.4.5 COM Port
The COM port and baud rate used by your computer to communicate with the
AIMMS CPM is modified using this menu item. This should not be confused with the
communication settings used internally by the AIMMS-20 (see Section 4.5)