RETE / POWER
INSERITO / ON
TAMPER
ON
UNITA' CENTRALE /
CENTRAL UNIT
AF994
ZONE
A2
EXCLUDE
ZONE
B
EXCLUDE
ZONE
C
EXCLUDE
ZONE
A1
EXCLUDE
R=47KOhm
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
COD.
AF45342
1
2
3
Pre-alarm
signalling
device
cod.45381
1 +
2 –
3 T
2 +
1 –
COD. AF45399
AF45360
Detector NC
contacts
Example of AF45360
and AF958 detector
connection.
This connection can be
performed also on
zones A1and A2
Diagram 2 - Connection to AF994
Auxiliary indoor siren
N
S
TAMPER
Anti-tampering magnetic
contact cod. AF901
SIREN AF - AF53900
Acoustic horn connection terminal
Acoustic horn connection terminal
Flashing device connection terminal
Flashing device connection terminal
Power
Power supply –
Anti-tampering microswitch (tamper)
Anti-tampering microswitch (tamper)
Positive NC siren control
Positive NC flashing device control
Interrupted flashing device filament signal (towards GND)
R
TAMPER
AF45339
1
–
2
+
3
4
5
N.C.
6
TC
BLOCCO RELÈ
RELA
Y OUT
12V —
(10,5…14)
––
1
+
2
–
3
TC
4 5
U
6 7
24h
AF958
OUT
TAMPER
GND C/BAT GND IN2 GND IN1 GND IN/BL
–
+
ALIM
To the TAMPER LINE
R
JP2
Terminal board
AF998CE
R=47KOhm
To the
TAMPER LINE
Note 1:
for connections related to
distances higher than 30 cm, use
a shielded cable (with a shield
central side earthed)
Note 2:
the wiring diagram reports
the connection of the channel 2. It
is necessary to program number 5,
6, 7, 8, using this wiring diagram
(see pag. 24)