Procedure
1. Navigate to
Configuration
>
System settings
>
Alert Configuration
.
2. In the
Alerts
field, click
Enabled
.
3. In the Alerts and Remote System Log Configuration section, in the
SNMP Trap
column,
select the required SNMP trap check boxes.
For Avaya SAL systems, select the check box in the heading row of
SNMP Trap
column to
select all the available SNMP traps.
4. Click
Apply
.
Configuring a user account for SNMP v3 traps
About this task
To configure an SNMP v3 traps, you must associate a user account with the traps. The password
of this user account is used to encrypt the SNMP v3 traps. The same password must be used by
the SNMP v3 trap receiver to decrypt trap information.
Before you begin
Log into the iDRAC9 web interface using the IP address and login details that were specified while
configuring iDRAC. See
Avaya iDRAC9 Best Practices
document for configuring the iDRAC.
Configuration
October 2019
Installing the Avaya Converged Platform 130 Series
78